Silo





         GENERAL INSPECTION



         Design vs works executed




             INCLUDES:
             ▪   Verification that the silo was erected according to the qualities and original
                 design.
             ▪   To be done at least once  during the life of silo if a correct silo construction is

                 in doubt.


            GOOD PRACTICE
             ▪   To be done preferably with empty and clean silo and including internal
                 inspection
             ▪   Inspector to check for evidences of deficient erection (bad quality of
                 work/material or discrepancies vs original design).



            REMARKS
             ▪   Modifications from the original design and retrofitting must pass the

                 engineering review and validation process.