Page 105 - GM E-BOOKLET 2022
P. 105

4.2. RETROFITTING OF 37°F/B PROBE IN PLACE OF 70° F/B NGFC PROBE

                     Based  on  experience  SCR  recommended  that  all  B-Scan  machines
                     should have 37° F/B Probes, in addition to 70° F/B probes (central, GFC
                     and NGFC). Anyhow 0° probe is common in all USFD machines.

                     This  item  (Item  no.1355)  was  raised  in  minutes  of  10th  Extraordinary
                     meeting (on-line) of Track standards committee on 22nd June 2021. The
                     committee recommendations are:
                    In existing SRT/DRT channels for 70º Non-Gauge face probes should be
                     used  to  accommodate  37º  probes  for  detection  of  bolt  hole  cracks  in
                     alternate rounds of USFD testing in Zonal Railways.
                    Based  on  the  above  recommendation  the  SC  Division  has  already
                     modified 3 No B-Scan DRT m/cs, 2 No A-Scan DRT m/cs and 1 No A-Scan
                     SRT m/c with the provision of 37º probes in the place of 70ºNGFC probes.
                    The  division  will  do  USFD    Rail  testing  by  using  with  37º  probes  and

                     70ºNGFC probes in alternative rounds simultaneously.


















                     Bolt Hole Cracks Detected By USFD B Scan Machine From 01.04.2022 To
                                                16.11.2022 in SC Division
                   SrDEN/       TOTAL IMR        TOTAL            TOTAL          IMR DUE TO BOLT HOLE
                     DEN                         IMRW           IMR/IMRW                  CRACK
                    North            12             0               12                       10
                    South            38             1               39                       33
                   Central           10             1               11                        8
                    West             9              3               12                        6

                    TOTAL            69             5               74                       57

                                              Total IMR detected = 74 Nos
                                            Total IMR of bolt hole crack = 57
                                Percentage of bolt hole crack = 57/74 x 100 = 77.03%




                                                           103
   100   101   102   103   104   105   106   107   108   109   110