Page 280 - GM E-BOOKLET 2022
P. 280

ii)      ROOT CAUSE ANALYSIS FOR FAILURES OF  INPUT CHOKES DUE TO WATER
                     ENTRY IN M/S SIEMENS HLCs


                     ELS/LGD has advised about rain water leakage through Outlet Louvers
                     of  Hotel  load  converters  into  the  machine  room  due  to  improper
                     design of Outlet louvers. Rain water is seeping through outlet louvers
                     and stagnating below hotel load converters and resulting into failure
                     of  input  chokes.  M/s  Siemens  has  accepted  the  observations  of

                     ELS/LGD and replaced all old design filters with modified arrangement
                     to  prevent  failure  of  input  chokes  and  improve  reliability  of
                     locomotives.
                         OLD DESIGN LOUVER                          NEW DESIGN LOUVER