Page 283 - GM E-BOOKLET 2022
P. 283

ENERGY SAVING MEASURES


            i)       MODIFICATION  TO  IMPELLER  OF  TRACTION  CONVERTER  OIL  PUMP
                     (SRMPH)  TO  REDUCE  THE  LOAD  CURRENT/  POWER  CONSUMPTION  OF
                     THE MOTOR IN GTO LOCOMOTIVES


                            Shed has taken up an energy conservation initiative in 3-phase
                     GTO  Electric  locomotives  by  reducing  the  impeller  diameter  of

                     traction converter oil circulating pump (SRMPH) of M/s. FLOWWELL &
                     M/s. SHIL makes to reduce excess pressure in the oil cooling circuit and
                     thereby  achieving  energy  conservation  by  reducing  power

                     consumption of the pump.


                            The impeller diameter of SRMPH has been reduced in-house from
                     198 mm to 160 mm in M/s. FLOWWELL SRMPH and from 202 mm to 175

                     mm in M/s. SHIL makes SRMPH, thereby achieved reduction in the load
                     current/power consumption of the motor from 11 KW to 6.3 KW. This

                     reduction in the power consumption of the motor has been resulted in
                     energy  conservation  in  three  phase  electric  locomotives  thereby

                     achieved  42.7%  reduction  in  energy  consumption.  The  reduction  of
                     pressure  also  helped  in  minimizing  the  radiator  failures  besides

                     achieving energy conservation.


                                                      Impeller               Oil            Rating of the
                                Make
                                                     Diameter            Pressure                pump

                                       Before          198mm           4.6kg/ cm           11 Kw/21Amps
                                                                                     2
                          FLOW
                           WELL         After          160mm                 2.6          6.3 Kw/12 Amps
                                                                         Kg/cm
                                                                                   2
                                                                                     2
                                       Before          202mm           3.6kg/ cm           11 Kw/21 Amps
                                        After          175mm                 2.6          6.3 Kw/12 Amps
                           SHIL                                          Kg/cm
                                                                                   2











                                                             281