iv.   Modification of the D1 emergency valve for increasing its height

                 In light of recent instructions to crew, the ALP was advised to be in alert and standing
                 position  in  the  event  of  an  approaching  signal  aspect  and  also,  he  must  be  ready  to
                 apply the emergency brakes. The existing height of the D1 emergency valve (120 mm to
                 floor)  was  not  sufficient  for  the  reach  of  ALP  in  standing  position.  As  such  shed  has
                 performed a modification to the emergency valve to increase its height (400 mm to floor)
                 which  the  ALP  can  now  easily  reach  without  compromising  the  signal  aspect.  This
                 modification has been completed on 07 locos so far and in is progress.














                     v.   Modification to SPIC/SC No. 200107

                              BEFORE               AFTER               BEFORE                AFTER












                            Provision of Electronic water level      Provision of Water level gauge on
                               sensor on roof mounted tank                 underslung water tank

                       •  New SPIC no. 200107 of SC division was commissioned on 23-03-2022. It was
                          received to DLS/MLY after manufacturing by M/s ICF, Chennai.
                       •  The  SPIC  did  not  have  a  provision  for  checking  the  water  level  in  the  roof
                          mounted main water tank.
                       •  Also, no water level gauge provided for the underslung water tank as well.
                       •  DLS/MLY have modified the new SPIC by providing an Audio-Visual alert along
                          with electronic water level sensor. Now Crew will receive AV alert whenever the
                          water level in the main tank reduces.
                       •  In  addition  to the  above,  a Water level gauge  has  also  been  provided  on  the
                          underslung water tank.

                    vi.   Developed a Mobile Single Car Test Rig for DEMU TCs