performance in hygiene-critical applications. The   applied and maintained, there is always a risk that
       range is carefully designed so that fans and cooling   the coating could become damaged while the motor
       ribs are not required, thereby allowing for   is in operation. Should this happen, then the
       completely smooth outer casings with non-drive   contamination resistance of the geared motor would
       ends that are sealed. This allows the IE4 super-  be reduced. Adopting the principles of HACCP,
       premium-efficiency motor to be offered with up to   many manufacturers are choosing to specify
       IP69K rating – which protects against high-pressure   stainless steel geared motors where they are likely
       washers and steam cleaning.          to be operating in an area with risk of mechanical
         The elimination of venting elements creates a   damage.
       smooth outer surface, which provides a higher   Stainless steel geared motors – as found within
       cleanability of the motor casing and prevents re-  the HiflexDRIVE range – meet all the regulations set
       infection of the local environment caused by air   out by organisations such as the FDA and NSF
       movement from a cooling fan. While specialist   without the need for specialist coatings. As a base
       coatings perform exceptionally well when correctly   material, stainless steel is inherently resistant to

                           June 2020 • INDUSTRIAL TECHNOLOGY EXTRA! • p11