Technical Data



              3.  Technical Data


              3.1.  Inputs/Outputs

                      Endwinding Vibration Input
                      Quantity                                    2
                                                                  Each connector supports up to 1 current input
                                                                     and 1 voltage input
                      Connector                                   6-pole Terminal Block Connector:
                                                                     Conductor cross section min/max
                                                                         0.08 to 1.3 mm² (28 AWG/16 AWG)
                                                                     Terminal torque min/max
                                                                         0.2/0.25 Nm
                                                                     Tool blade dimensions
                                                                         0.4 x 2.5 mm
                      Input Range (maximum)                       ±2.5 V
                      Input Impedance                             High-Z


                      Termination Box Power Output
                      Quantity                                    1
                      Connector                                   3-pole Terminal Block Connector:
                                                                     Conductor cross section min/max
                                                                         0.08 to 1.3 mm² (28 AWG/16 AWG)
                                                                     Terminal torque min/max
                                                                         0.2/0.25 Nm
                                                                     Tool blade dimensions
                                                                         0.4 x 2.5 mm
                      Power Output                                ±12 Vdc
                                                                  1 W


              3.2.  Data Acquisition
                      Monitored Asset s                           1
                      SM Sampling                                 24-bit resolution
                                                                  8192 Hz



              3.3.  Environmental Conditions

                        Refer to the GuardII+ Platform User Manual.











                                                              5
                                                                                          www.irispower.com