GuardII+ SM Card Operation



                        •  The peak value for the GV input occurs at 2:30 am.

                        •  The peak value for the G1 input occurs at 3:30 am.
                        •  The peak value for the G2 input occurs at 3:30 am.

                        •  The peak value for the TV input occurs at 1:00 pm.
                        The Archive for this day will contain the following measurements:
                        •  The measurement collected at 2:30 am (the measurement with the peak GV value).

                        •  The measurement collected at 3:00 am (the measurement after the first peak of the
                            day).

                        •  The measurement collected at 3:30 am (the measurement with the peak G1 and G2
                            values).

                        •  The measurement collected at 1:00 pm (the measurement with the peak TV value).

              4.5.  Modbus Outputs

                        SM Measurement data is hosted inside the monitor for an external Modbus master to read.
                     To access the data registers, connect to the GuardII+ using Ethernet and query the monitor
                     using  the  standard  Modbus  over  TCP/IP  protocol.    This  data  is  updated  during  every
                     measurement cycle.  Modbus data outputs include:

                        •  Measurement time
                        •  Measurement status per input

                        •  Peak-to-peak and RMS numbers per input
                        Refer to Section 8.2 for details of the SM Modbus register addresses.

              4.6.  GuardII+ Alerts

                        Alerts in a GuardII+ SM system are based on the Alert thresholds configured in IAM; when
                     the measurement results exceed one or more of the Alert thresholds, the Alert is asserted.
                                     NOTE:
                                     There are two configurations that need to be completed using IAM for the
                                     Alert feature to function fully:
                                       •  First, there is a general Alert Relay behavior that must be set to a
                                           selection  other  than  ‘Disabled’;  if  the  Alert  Relay  behavior  is  not
                                           configured, then the Alert Relay will not function, although Archived
                                           measurements  and  Modbus  data  will  still  report  an  Alert  when  it

                                           occurs.
                                       •  Second, the Alert thresholds must be set.
                                     Refer to Section 6.3 for details on GuardII+ configuration.