Page 142 - Pharmaceutics IV (02-06-01305)
P. 142

Quality control
                          testing

277

  Ophthalmic DD: quality control testing

    • Sterility testing
     • Foreign and particulate matter
      ➢ All ophthalmic solutions should be inspected for the presence of

         observable foreign and particulate matter.
      ➢ Ophthalmic solutions should be essentially free from particles that

         can be observed on visual inspection (visible particulates).
      ➢ Subvisible particulates (10, 25 & 50 µm) should be detected using

         light obscuration and microscopic procedures for the
         determination, identical to those for injections

278