Page 7 - type de document
P. 7

EOS          90395-A-PHY-0002-Column feet assembly & setting




                   d.  Remove the locks from each of

                      ‘Levelling bolts’ on each quadrant (see
                      image below)

                   e.  Using a 17mm socket, turn all
                      levelling bolts CCW to their lowest
                      position.


                   f.  Strike a line on each of the levelling
                      bolts to use as reference when
                      counting turns. (see image below)

                   g.  Using this reference line give all
                      levelling bolts 9 complete turns CW.

                      This raises each quadrant to the
                      middle of its total range of motion.
                      (see information box for explanation)





























                               IMPORTANT: It has been previously determined that the full range of motion of
                               the Nivell levelling bolts is approximately 18 turns so the middle position is 9 turns
                               from either end. This is just a convenient starting point.