EOS          90395-A-PHY-0002-Column feet assembly & setting




               8.  IDENTIFYING GOOD ANCHOR HOLES TO AVOID REBAR COLLISIONS

                   a.  Locate the levelling plates and its

                      required mounting hardware (guiding
                      pin and counter sunk screw).
                   b.  Prior to mounting the levelling plate,
                      mount the ‘Guiding-pin’ onto the
                      Nivell plate in its corresponding

                      location based on the layout of the
                      levelling plate shown on the image
                      above. The hole with the pin (A)
                      should have a snap ring inserted and
                      sits across the counter-sunk (C) hole

                   c.  Place each levelling plate on top of its
                      corresponding Nivell.  (Plates should
                      be marked accordingly). Orientation is
                      important.