EOS 90395-A-PHY-0002-Column feet assembly & setting
8. IDENTIFYING GOOD ANCHOR HOLES TO AVOID REBAR COLLISIONS
a. Locate the levelling plates and its
required mounting hardware (guiding
pin and counter sunk screw).
b. Prior to mounting the levelling plate,
mount the ‘Guiding-pin’ onto the
Nivell plate in its corresponding
location based on the layout of the
levelling plate shown on the image
above. The hole with the pin (A)
should have a snap ring inserted and
sits across the counter-sunk (C) hole
c. Place each levelling plate on top of its
corresponding Nivell. (Plates should
be marked accordingly). Orientation is
important.