785 AXIAL MAINTAINED LOAD PROOF TESTING OF WORKING PILES
      • Type of test: site specific.
      • Pile group designation: site specific.
          - Number of piles to be tested: site specific.
          - Test pile construction: site specific.
          - Test load (maximum): site specific.
      • Special requirements: site specific.

810 TIMING OF PILE LOAD TESTING
      • Period between installation and load testing (minimum): Until concrete achieves
          sufficient strength to avoid damage when tested .

825 WORK TO PILE HEADS AFTER TESTING
      • Preliminary/ anchor piles: Cut down to site specific depth below blinding layer to
          ground slab and backfill hole with site specific fill .
      • Working piles: site specific .

          COMPLETION

920 PILING GUARANTEE
      • Type: Insurance backed. Administered by an independent insurance protection
          company.
          - Guarantee period (minimum): 25 years from completion.
             Documentation: Provide certificates/ guarantees at completion of piling works.