Page 101 - CRS Engineering
P. 101
Proforma for Joint Inspection on R. A. T.
For the Year 2020 -21
SI Description Remarks
No
General Particulars of RAT
Name of the tank Badrareddy Gunta Tank
District Chittoor District
Name of the Village and Mandal Narayanapuram Village, Srikalahasti Mandal
Latitude & Longitude Lat 13" - 45' - 26" Long 79" - 40' - 25'
Affected Railway Bridge and Km The Tank Lies in-between Bridge No:- 70&57 /
Railway section in between stations Yellakaru
Distance from Railway Bridge to weir 4.50 Kms from the Railway line to the tank.
( Along the Course of Nallah )
II Standard Hydraulic Details
Catchment Area 0.63 Sq miles
Capacity of the tank 13.10 MCFT
Lowest Bed Level -I- 97.20M
Full Tank Level ( F.T.L ) + 100.00M
Maxim Water Level ( M.W.L ) + 100.60M
Danger Level ( D.L ) + 100.85M
Top of Bund Level ( T.B.L ) + 101.50M
8 Top Width of the Bund 1.20M, 1.50M ( Present Top Width )
Side Slopes AT FRONT:- 1 V2 : 1 , AT REAR :- 2:1
10 Area of Submergence at FTL
11 Area of Submergence at MWL
12 Are there any tanks in the Catchment of NO
this tank
13 Are these tanks also classified as RATs
14 Names and details of these tanks
Surplus Weir
III
Number of Surplus Weirs ONE NUMBER ONLY ( 1 No Only )
I enaths of Surplus Weir 9.50 M
Tvpe of Surplus Weir B.C WEIR
Design Discharge 449 Cusecs
IV Sluices
Number of Sluices ONE NUMBERS ONLY ( 1 No Only )
Location of Sluices
^^avimiim designed discharge 2.50 CUSECS
-unctional or not FUNCTIONAL
4
Inspection details
35-02-2020
)Date of Inspection — O^'
1) Sri. C. Willson Babu,
i^Name& Designation of the Inspection
Assistant Divisional Engineer ,
South Central Railway
RENIGUNTA
2) Sri. C.Adinarayana Naidu, B.Tech..
Deputy Executive Engineer,
Irrigation Sub Division
3) Sri. K Rajesh,B.Tech.,
Assistant Executive Engineer ,
Irrigation Section
SRIKALAHASTI