Page 119 - CRS Engineering
P. 119

Description                                          rxciiicii rvo
  SI
 Mo
     General Particulars of RAT
                                                     Uranduru Tank
     Name of the tank
                                                     Chittoor District
     District
                                                     Uranduru Village, Srikaiaiiasti Mandal
     Name of the Village and Mandal
     Latitude & Longitude                            Lat 13° - 44' - 30" Long 79° - 39' - 30"
                                                    The Tank Lies in-between Bridge No:-70&57 /
     Affected Railway Bridge and Km
                                                     Yellakaru
      R.ailway section in between stations
                                                     Railway line Crosses the tank bund and   fore sh
      Distance from Railway Bridge to weir
                                                     of the tank.
       Along the Course of Nallah )
      Standard Hydraulic Details
                                                     27.47 Sq miles
      Catchment Area
      Capacity of the tank                           98.00 M.C.F.T
                                                     +66.92M
      Lowest Bed Level
                                                     +70.58M
      Full Tank Level ( F.T.L )
                                                     +71.34M
      Maxim Water Level ( M.W.L )
                                                     +71.95M
      Danger Level ( D.L )
                                                     +71.95M, +72.25M, +72.56M.
      Top of Bund Level ( T.B.L )
                                                     1.20M, 1.80M and 5.00M ( Present Top Width
      Top Width of the Bund
                                                     AT FRONT:- 1 Vi : 1 , AT REAR      2:1
      Side Slopes
   10 Area of Submergence at FTL
      Area of Submergence at MWL
                                                                             Yes
   12 Af-e there any tanks in the Catchment of
  _1  Are these tanks also classified as RATs
      Names and details of these tanks
   14
  TFl SiiTpms Weir
      Number of Surplus Weirs                        Two Numbers Only &One Surplus Course
      I^nnt-hs ofSurplus Weir                        1) 15.30M, 2) 17.65M, 3) 36.00M.
      ^f^;g]^Surplus Weir                            B.C WEIR
              Discharge                              3861 Cusecs



  Location of Sluices
  Maximum designed discharge                     2.50 CUSECS
  Functional or not                              FUNCTIONAL
  A) Inspection details
  i)Date of Inspection                                              ^5-02-2020
  ii)Name& Designation of the Inspection                      1) Sri. C. Willson Babu
                                                           Assistant Divisional Enginepr
                                                               South Central Railwav
                                                                     RENIGUNTA     "
                                                      2) Sn. C.Adinarayana Naid^jTil^::!^
                                                            Deputy Executive Engineer
                                                               Irrigation Sub Division


                                                             3) Sri. K Rajesh,B.Tech.;
                                                           Assistant Executive Engineer           —"
                                                                 Irrigation Section
                                                                   SRIKALAHASTI           ^