Page 169 - CRS Engineering
P. 169

iii) If tank quality for classification as RAT                        YES

                B) Tank Bund
                i) Is the top level of the bund uniform and                           YES
                as oer the standards?
                ii) Is the top width of the bund as per                               YES
                standards?
                iii) Are the slopes as per the standards?                             YES
                iv) Any dangerous gullies or scour of the                             No
                bund?
                C) Surplus Weir
                i) Condition                                                         Good
                ii) Is the Length adequate for Design                       No , it is not adequate
                discharae?
                iii) Is Danger Level marked                                          Yes,
                D) Condition of the Sluices                                          Good
                E) Any Past history of Breach of the                                  No
                tank if so, details.
                D)                                            Surplus weir no.l was reconstructed early Year.














                            Assist^t Engineer,                           DeputV E^ecU(\\}e Engineer,
                             Irrigation Section,                           Irrigation Sub-Division,

                                 YERPEDU                                       SRIKALAHASTI.






                                                                                               ^ /l-
                                                                        Assistant Divisional Engineer,
                                                                            South Central Railway,
                                                                                 RENIGUNTA.
   164   165   166   167   168   169   170   171   172   173   174