Page 164 - CRS Engineering
P. 164

Proforma for Joint Inspection on R. A. T.
                                               For the Year 2020 -21
             s                   Description                                        Remarks
            No
              1 General Particulars of RAT
                Name of the tank                               L. K Venkatapuram Tank
              2 District                                       Chittoor District

              3 Name of the Village and Mandal                 Kobaka Village, Yerpedu Mandal
              I  Latitude & Longitude                          Lat 13° - 40' -20" Long 79° - 36' -50"
              5 Affected Railway Bridge and Km                 Bridge No:-89, Location 64 / 24 - 26
              6 Railway section in between stations            Yearpedu - Rachagunneri
              7 Distance from Railway Bridge to weir
                                                               j.du KMs from tne Railway line to tne tank
                ( Along the Course of Nallah )
             II Standard Hydraulic Details
                Catchment Area                                2.38sqkm
              2 Capacity of the tank                          9.20M.C.F.T
              3 Lowest Bed Level                              + 98.45 M
                Full Tank Level ( F.T.L )
              I                                               + 100.00M
              5 Maxim Water Level ( M.W.L )                   + 100.60M
              6 Danger Level ( D.L )                          + 100.90M
              7 Top of Bund Level ( T.B.L )                   + 101.50M
              8 Top Width of the Bund                         3.00M ( Present Top Width )
              9 Side Slopes                                   AT FRONT:- 1 Vz : 1 , AT REAR :- 2:1
            10 Area of Submergence at FTL                     8.60 Hectors.
            11 Area of Submergence at MWL                     9.90 Hectors.
            12 Are there any tanks in the Catchment of                                NO
            13 Are these tanks also classified as RATs                                 -
            14 Names and details of these tanks                                        -
           III Surplus Weir                                                            -
              1 Number of Surplus Weirs                       ONE NUMBER ONLY (1 NO Only)
              2 Lengths of Surplus Weir                       12.00M.
              3 Type of Surplus Weir                          B.C WEIR
             4 Design Discharge                               45.60 Cusecs
            IV Sluices
             1 Number of Sluices                              THREE NUMBER ONLY (3 NO Only)
             2 Location of Sluices                            AT125M, AT435 M, AT 725 M.
             3 Maximum designed discharge                     2.30 Cusecs
             4 Functional or not                              Sluice No.l & 2 is Damaged.
             V A) Inspection details
                )Date of Inspection                                            ^-02-2020
                i)Name& Designation of the Inspection                     1) Sri. C. Wilison Babu,
                                                                        Assistant Divisional Engineer,
                                                                            South Central Railway
                                                                                 RENIGUNTA
                                                                  2) Sri. C.Adinarayana Naidu, B.Tech.,
                                                                         Deputy Executive Engineer,
                                                                            Irrigation Sub Division


                                                                           3) Sri. K. Harikrishna
                                                                            Assistant Engineer,
                                                                              Irrigation Section
                                                                                  YERPEDU
   159   160   161   162   163   164   165   166   167   168   169