Page 164 - CRS Engineering
P. 164
Proforma for Joint Inspection on R. A. T.
For the Year 2020 -21
s Description Remarks
No
1 General Particulars of RAT
Name of the tank L. K Venkatapuram Tank
2 District Chittoor District
3 Name of the Village and Mandal Kobaka Village, Yerpedu Mandal
I Latitude & Longitude Lat 13° - 40' -20" Long 79° - 36' -50"
5 Affected Railway Bridge and Km Bridge No:-89, Location 64 / 24 - 26
6 Railway section in between stations Yearpedu - Rachagunneri
7 Distance from Railway Bridge to weir
j.du KMs from tne Railway line to tne tank
( Along the Course of Nallah )
II Standard Hydraulic Details
Catchment Area 2.38sqkm
2 Capacity of the tank 9.20M.C.F.T
3 Lowest Bed Level + 98.45 M
Full Tank Level ( F.T.L )
I + 100.00M
5 Maxim Water Level ( M.W.L ) + 100.60M
6 Danger Level ( D.L ) + 100.90M
7 Top of Bund Level ( T.B.L ) + 101.50M
8 Top Width of the Bund 3.00M ( Present Top Width )
9 Side Slopes AT FRONT:- 1 Vz : 1 , AT REAR :- 2:1
10 Area of Submergence at FTL 8.60 Hectors.
11 Area of Submergence at MWL 9.90 Hectors.
12 Are there any tanks in the Catchment of NO
13 Are these tanks also classified as RATs -
14 Names and details of these tanks -
III Surplus Weir -
1 Number of Surplus Weirs ONE NUMBER ONLY (1 NO Only)
2 Lengths of Surplus Weir 12.00M.
3 Type of Surplus Weir B.C WEIR
4 Design Discharge 45.60 Cusecs
IV Sluices
1 Number of Sluices THREE NUMBER ONLY (3 NO Only)
2 Location of Sluices AT125M, AT435 M, AT 725 M.
3 Maximum designed discharge 2.30 Cusecs
4 Functional or not Sluice No.l & 2 is Damaged.
V A) Inspection details
)Date of Inspection ^-02-2020
i)Name& Designation of the Inspection 1) Sri. C. Wilison Babu,
Assistant Divisional Engineer,
South Central Railway
RENIGUNTA
2) Sri. C.Adinarayana Naidu, B.Tech.,
Deputy Executive Engineer,
Irrigation Sub Division
3) Sri. K. Harikrishna
Assistant Engineer,
Irrigation Section
YERPEDU