Page 170 - CRS Engineering
P. 170
Proforma for Joint Inspection on R. A. T.
For the Year 2020 -21
s Description Remarks
No
I General Particulars of RAT
1 Name of the tank MadhavamalaTank
2 District Chittoor District
Name of the Village and Mandal MadhavamalaViilage, Yerpedu Mandal
I Latitude & Longitude Lat 13° - 39' -18" Long 79° - 34' -03"
Affected Railway Bridge and Km Bridge No:-89, Location 64/ 24 - 26
Railway section in between stations Renegunta Yearpedu
1 Distance from Railway Bridge to weir
4.50KMS from the Railway line to the tank
( Along the Course of Nallah )
II Standard Hydraulic Details
1 Catchment Area 3.25 sqkm
2 Capacity of the tank 38.20M.C.F.T
Lowest Bed Level + 96.30 M
I Full Tank Level ( F.T.L ) + 100.00M
5 Maxim Water Level ( M.W.L ) +100.60M
6 Danger Level ( D.L ) + 100.90M
7 Top of Bund Level ( T.B.L ) + 102.10M
8 Top Width of the Bund 3.00M ( Present Top Width )
9 Side Slopes AT FRONT:- 1 1/2 : 1 , AT REAR :- 2:1
10 Area of Submergence at FTL 2.90 Hectors.
11 Area of Submergence at MWL 3.70 Hectors.
12 Are there any tanks in the Catchment of NO
13 Are these tanks also classified as RATs -
14 Names and details of these tanks -
III Surplus Weir -
1 Number of Surplus Weirs ONE NUMBER ONLY (1 NO Only)
2 Lengths of Surplus Weir 25.00M.
3 Type of Surplus Weir B.C WEIR
4 Design Discharge 69.00Cusecs
IV Sluices
1 Number of Sluices FOUR NUMBER ONLY (4 NO Only)
2 Location of Sluices AT 220 M, AT 540 M, AT750 MAT 870 M
3 Maximum designed discharge 2.50 Cusecs
4 Functional or not Sluice No. 4 is damaged.
V A) Inspection details
)Date of Inspection ^-02-2020
ii)Name& Designation of the Inspection 1) Sri. C. Willson Babu,
Assistant Divisional Engineer,
South Central Railway
RENIGUNTA
2) Sri. C.Adinarayana Naidu, B.Tech.,
Deputy Executive Engineer,
Irrigation Sub Division
3) Sri. K. Harikrishna
Assistant Engineer,
Irrigation Section
YERPEDU
/