Proforma for Joint Inspection on R. A. T.

                                              For the Year 2020 -21
            SI                  Description                                       Remarks
           No
             I General Particulars of RAT
             1 Name of the tank                              Seethrampeta Tank
             2 District                                      Chittoor District

             3 Name of the Village and Mandal                 Seethrampeta Village, Yerpedu Mandal
             4 Latitude & Longitude                          Lat 13° - 41' -08" Long 79° - 35' -09"
             5 Affected Railway Bridge and Km                Bridge No:-89, Location 64/ 24 - 26
             6 Railway section in between stations           Yearpedu - Rachagunneri
             7 Distance from Railway Bridge to weir
                                                             2.00 KMs from the Railway line to the tank
               ( Along the Course of Nallah )
            II Standard Hydraulic Details
             1 Catchment Area                                3.20 sqkm
             2 Capacity of the tank                          5.45M.C.F.T
             3 Lowest Bed Level                              + 98.51M
             4 Full Tank Level ( F.T.L )                     + 100.00M
             5 Maxim Water Level ( M.W.L )                   +100.60M
             6 Danger Level ( D,L )                          + 100.90M
             7 Top of Bund Level ( T.B.L )                   + 102.10M
             8 Top Width of the Bund                         3.00M ( Present Top Width )
             9 Side Slopes                                   AT FRONT:- 1 Vz : 1 , AT REAR :- 2:1
            10 Area of Submergence at FTL                    8.90 Hectirs.
            11 Area of Submergence at MWL                    9.80Hectirs.
            12 Are there any tanks in the Catchment of                               NO
            13 Are these tanks also classified as RATs                                -
            14 Names and details of these tanks                                       -
           III Surplus Weir                                                           -
             1 Number of Surplus Weirs                       ONE NUMBER ONLY( 1 NO Only)
             2 Lengths of Surplus Weir                       20.0m
             3 Type of Surplus Weir                          B.C WEIR
             4 Design Discharge                              35.40 Cusecs
            IV Sluices
             1 Number of Sluices                             TWO NUMBER ONLY (2N0 Only)
             2 Location of Sluices                           AT 150 M. AT 610 M
             3 Maximum designed discharge                    2.30 Cusecs
             4 Functional or not                             FUNCTIONAL
             V A) Inspection details
               i)Date of Inspection                                            3^8-02-2020
               ii)Name& Designation of the Inspection                     1) Sri. C. Willson Babu,
                                                                       Assistant Divisional Engineer,
                                                                           South Central Railway
                                                                                 RENIGUNTA
                                                                  2) Sri. C.Adinarayana Naidu, B.Tech..
                                                                        Deputy Executive Engineer,
                                                                           Irrigation Sub Division


                                                                           3) Sri. K. Harikrishna
                                                                            Assistant Engineer,
                                                                              Irrigation Section
                                                                                  YERPEDU