Page 190 - CRS Engineering
P. 190
Proforma for Joint Inspection on R. A. T.
For the Year 2020-21
SI Description Remarks
No
I General Particulars of RAT /
YearpeduTank '
1 Name of the tank
2 District Chittoor District
3 Name of the Village and Mandal Yearpedu Village, Yerpedu Mandal
4 Latitude & Longitude Lat 13° - 41' -05" Long 79° - 35' -36"
5 Affected Railway Bridge and Km Bridge No:-89, Location 64/ 24 - 26
6 Railway section in between stations Yearpedu - Rachagunneri
7 Distance from Railway Bridge to weir
O.SOKMs from the Railway line to the tank
( Along the Course of Nallah )
II Standard Hydraulic Details
1 Catchment Area 4.20 sqkm
2 Capacity of the tank 50.20 M.C.F.T
3 Lowest Bed Level + 97.25M
4 Full Tank Level ( F.T.L ) +100.00M
5 Maxim Water Level ( M.W.L ) + 100.60M
Danger Level ( D.L ) +100.90M
6
7 Top of Bund Level ( T.B.L ) + 102.10M
8 Top Width of the Bund 3.00M ( Present Top Width )
9 Side Slopes AT FRONT:- 1 Vz : 1 , AT REAR :- 2:1
10 Area of Submergence at FTL 16.70 Hectirs.
11 Area of Submergence at MWL 17.90Hectirs.
12 Are there any tanks in the Catchment of NO
13 Are these tanks also classified as RATs -
14 Names and details of these tanks -
TII Surplus Weir -
Number of Surplus Weirs ONE NUMBER ONLY( 1 NO Only)
1
2 Lengths of Surplus Weir 9.00 M,
3 Type of Surplus Weir B.C WEIR
4 Design Discharge 35.40 Cusecs
IV Sluices
FOUR NUMBER ONLY (4 Nos only)
1 Number of Sluices
AT 160. M.
2 Location of Sluices
3 Maximum designed discharge 2.40 Cusecs
Sluice No.2 Damaged to be Reconstruct
4 Functional or not
V A) Inspection details
^J&-02-2020
i)Date of Inspection
ii)Name& Designation of the Inspection
—" 1) Sri. C. Willson Babu,
Assistant Divisional Engineer,
South Central Railway
RENIGUNTA
2) Sri. C.Adinarayana Naidu, B.Tech.,
Deputy Executive Engineer,
Irrigation Sub Division
3) Sri. K. Harikrishna
Assistant Engineer,
Irrigation Section
YERPEDU