                                        proforma for submission of RAT inspection report
                                           DESCRIPTION                                  REMARKS
                   S  NO
                    I                 General Particulars of RAT
                                                                         Varadarajulapalle hissa cheruvu
                        Name of the Tank
                                                                         CHCm 009000PAK
                        Tank ID No.
                                                                         Chittoor
                        District
                        Name of the village & mandal                     Mapakshi(v) Chittoor(M)
                        Latitude & Longitude                             13''-12'-20" & 79°-08'-35"
                        Affected Railway Bridge & KM                     529 KM 25 / 6-7
                        RailwaySection & between sections                Chittoor-sidampalli
                        Distance from Railway Bridge toweir(along thecoursc ofNallah)
                                    Standard Hydraulic particiUars
                        Catchment Area                                   10.44 sq.km
                        Capacity of the Tank                             4.91 Mcft.
                        Lowest bed level                                 332,12
                        Full Tank Level (FTL)                      (M)   336.35
                        Maximum Water Level(MWL)                   (M)   337.00
                        Danger Level (PL)                                337.00
                        Top of Bund Level (TBL)                   (M)    337.92
                        Top width of bund                         (M)    3.00
                        Side slopes                                      front 1.5 :1 & rear 2:1
                     10  Area of submergence at FTL
                     11  Area of submergence at MWL
                     12  Are there any tanks in the catchment of this tank  No
                     13  Are there any tanks also classified as RATs?
                        Names & Details of these Tanks
                     14
                                           "Surplus weir
                     III
                        No of surplus weirs                              two
                        Lenghts of surplus weirs                 (M)     11.50 iVI & 28.35 M
                        Type of surplus weirs                            iVIasonry
                        Design Discharge                                 10847.88 cusec
                     IV                       Sluicc
                        No of sluices                                    1.00
                        Location of sluices
                        Maximum Design Discharge
                        Functional or not                                closed
                        A) Inspection Details
                         1. Date of Inspection                           10-02-2020
                        2. Name& Designation ofInspecting Officials      1.Sri G.Prasanth AEE, Irrigation Section Chittoor (M)
                                                                         2.Sri P.Prathapa Reddy, DEE, ISO aR
                                                                         3.Sri IVl.N.Krishnappa, ADEN/Pal<ala
                                                                         4.SriV.DIiamu Raju, SSE/PWAY, Chittoor

                        3, If the tank qualifyforclassification as RAT   Yes
                        B) Tank Bund
                         1. Is the top level of bund uniform and as per the standards  Yes
                        2. Is the top width of the bund as per the standards  Yes
                        3. Are the slopes as per standards               Yes
                        4. Any Dngerous gullies scource of the bund      No
                        C) Surplus Weir
                         1. Condition                                    Requires repairs
                        2. Is the length adequate for Design Discharge   Yes
                        3. Is danger level marked?
                         D)Condition of sluices                          closed
                         E) Anypast history of breach of the tank and ifso details?  No
                   REMARKS: tank is Ingood condition



                                                    \olU^
                                              Dy. Executive Engineer
           Assistant Executive Engineer
                                              <1R Sab Djvisioii,CHITTOO
             Irrigation Section,Chittoor,                                  Asst-Dlvl.Eng.neo'A"^
                                                                                     s.c.
                                                                                      pakala



















                           sHiim
   275   276   277   278   279   280   281   282   283   284   285