Page 283 - CRS Engineering
P. 283

Annexure II

                                          DESCRIPTION                                  REMARKS
                  S  NO
                                     General Particiilai s of RAT
                    I
                                                                        Kamminavani Cheruvu
                    1  \iame of the Tank
                                                                        CHCm 006000PAK
                    7  Tank ID No.
                                                                        Chittoor
                    2  District                          ^
                       \ame of the village & mandal                     Thimmasamudram(v) Chittoor(M)
                    3
                                                                        13°-14'-30"&79''-09'-45"
                    4  Latitude & Longitude
                    5  Affected Railway Bridge & KM                     572 KM 35 / 4-5
                       Raihvav Section & between sections               Chittoor-putalapattu
                    6
                       Distance from RaUway Bridge toweir (along the course ofNallah)
                    7
                                    Standard livdraulic particulars
                    11
                                                                        4.95 sq.km
                       Catchment Area
                    1
                       Capacit\' of the Tank                            2.54 Mcft.
                    2
                    3  Lowest bed level                                 287.67
                       Full Tank Level (FTL)                      (M)   289.25
                    4
                       Maximum WaterLevel(MWL)                    (M)   289.70
                    5
                    6  Danger Level (DL)                                289.70
                       TopofBund Level (TBL)                      (M)   290.63 M & 290.32 M
                    7
                       Top width ofbund                          (M)    3.00
                    8
                    9  Side slopes                                      front 1.5 :1 & rear 2'.1
                    10  Area of submergence at FTL
                    11  Area of submergence at MWL
                    12  Are there anv tanks in the catchment of this tank  No
                    13  Are there any tanks also classifiedas RATs?     No
                        Names & DetaUs of these Tanks
                    14
                                           Surplus weir
                    III
                     1  No of surplus weirs                             one
                    2   Lenghts ofsurplus weirs                  (M)    20.10
                     3  Type of surplus weirs                           BC weir
                    4   Design Discharge                                787.17 cusec
                    IV                        Sluiee
                     1  No of sluices                                   1 No
                     2  Location of sluices
                     3  Maximum Design Discharge
                     4  Functional or not                               closed
                    V   A) Inspection Details
                        1. Date of Inspection                           12-02-2020
                        2. Name c&. Designation ofInspecting Officials  1.Sri G.Prasanth AEE, Irrigation Section Chittoor (M)
                                                                        2.Sri P.Prathapa Reddy, DEE, ISO aR
                                                                        3.SriM.N.Krishnappa, ADEN/Pal<ala
                                                                        4.SriV.Dhamu Raju, SSE/PWAY, Chittoor
                        3. Ifthe tankqualify forclassification as RAT   Yes
                        B)Tank Bund
                        I. Is the top level of bund uniform and as per the standards  Yes
                        2. Is the top width of the bund as per the standards  Yes
                        3. Are the slopes as per standards              Yes
                        4. Any Dngerous gulliesscource of the bund      No
                        C) Surplus Weir
                        1. Condition                                    good-
                        2. Is the length adequate for Design Discharge  Yes
                        3. Is danger level marked?
                        D)Condition of sluices                          closed
                        E) Any past historyof breachofthe tank and ifso details?  No
                   REMARKS: tank is in good condition




                Assistant Executive Engineer               i>3vtelon,CHrrTOv:)P
                 Irrigation Section,Chittoor.                                     Asst DWl. Eno^neel
                                                                                            s.c.
                                                                                             pakai-a
   278   279   280   281   282   283   284   285   286   287   288