Annexure II

                                             fr»r submission of RAT inspection report
                                     description                                          REMARKS
         S  NO
                               General Particulars ol RAI
           1
                                                                        Kastlmri Nayani Cheruvu
           1   Sfame of the Tank
                                                                        CHCHI OOlOOOPAK
           9   rank ID No.
                                                                        Chittoor
           2   District
               Name ofthevillage &mandal                ^               Thimmasamudram (V) CHITTOOR (M)
           3
               TAltitude & Longitude                                    13°-14'-25"& 79°-09'-15"
           4                                                            575 KM 35 / 4-5
               A       Railwav Bridge & KM
               p.i,,.,.,, c:..finn &between sections                    Chittoor- Puthalapattu
           A
                                       to weir (along the course of Nallah)  0.15 KM
           7
                              Standard Hydraulic particulars
           n
                                                                        2.80 sq.km
           1   r^frhment Area
           7   r^apadtvof the'1 ank                                     4.13 IVIcft.
                                                                        293.20
               T      bed level
                                                                  (M)   296.15
           4   Full Tank Level (FTL)
               H-in^..m Water Level(MWL)                          (M)   296.60
            5
               P^nppr Level (DL)                                        296.60
            6
               TopofBund Level (TBL)                             (M)    297.52
            7
                Top widthofbund                                   (M)   3.00
            8
            9   Side slopes                                             front 1.5 ; 1 & rear 2:1
                Area of submergence at FTL
           10
                Area of submergence at MWL
            11
                Are there any tanks in the catchment of this tank       No
            12
                Are there any tanks also classified as RATs?            No
            13
            14  Names & Details of these Tanks
                                      Surplus weir
            III
            1   No of suiplus weirs                                     one
            2   Lenghts of surplus weirs                         (M)    32.00
            3   Type of suiplus weirs                                   Masonry
            4   Design Discharge                                        643 cusecs
            IV                           Sluice
            1   No of sluices                                            INo
            2   Location of sluices                                     Ch:150.00 M
            3   Maximum Design Discharge
            4   Functional or not                                       closed
            V   A) Inspection Details
                1. Date of Inspection                                    12-02-2020
                2. Name & Designation of Inspecting Officials           1.Sri G.Prasanth AEE, Irrigation Section Chittoor (IVl)
                                                                        2. Sri P.Pratliapa Reddy, DEE, ISO CTR
                                                                        3. SriM.N.Krislinappa, ADEN/Pal<ala
                                                                        4. SriV.Dhamu Raju, SSE/PWAY. Cliittoor
                3. If the tank qualify for classification as RAT        Yes
                B)Tank Bund
                1. Is the top level of bund uniform and as per the standards  yes
                2, Is the top width of the bund as per the standards     Yes
                3. Are the slopes as per standards                       Yes
                4. Any Dangerous gullies source of the bund              No
                C) Surplus Weir
                I, Condition                                             closed
                2. Is the length adequate for Design Discharge           Yes
                3. Is danger level marked?
                D)Condition of sluices                                   closed
                E) Anypast history of breach of the tank and ifso details?  No
          REMARKS: tank is in good condition


         A? Wit Executive 'trtgineer                            eer
                                        rRR Sob Dh'UJon,CHrrTOOP
        milgation Section,Chittoor.
                                                                         Asst. DWl.
                                                                         ^.T,,\c^,S.C.Kanway
                                                                                    PAKAi«^