Page 289 - CRS Engineering
P. 289
Annexure II
PROFORMA FOR SUBMISSION OF R.A.T INSPECTION REPORTS
S.NO. Description Remarks
I General particulars of RAT
1 Name of the tank RAMAUNGA SAMUDRAM CHERUVU
Tank ID CHCT0028000PAl<
2 District CHnTGOR
3 Name of village & Mandal Chinthapenta (V) Penumur Mandal
4 Latitude & Longitude 13° 22' 45" & 79° 14' 15"
5 Afficted Railway Bridge & KM 616 KM 48/8-9
6 Railway section and between stations SSE PW CrO PTT-PAK
Distance from Railway bridge to weir (along the course of
Nallah) 7.4 KM
7
Standard Hydraulic Details
11
Catchment Area 11.32 Sq.Miles
1
Capacityof the Tank 27.77Mcft
2
3 Lowest Bed Level + 338.17 M
4 Full Tank Level (FTL) + 342.14 M
Maximum water level (MWL) + 342.90 M
5
6 Danqer Level (DL)
7 Top of Bund Level (TBL) + 344.12 M
8 Top width of Bund 1.50 M
9 Side slopes Front 1.5:1 Rear 2:1
10 Area of submergence at FTL 6.40 M.Sq.feet 0.595 M.Sq.M
11 Area of submergence at MWL
12 Are there any tanks in the catchment of these tank ? yes
Are these tanks also classifed as RATs'?
13 yes
14 Names & Details of these tanks 15N0S
III Surplus weir
1 No. of surplus weirs INos.
2 Lengths of surplus weirs 52.73 M +8.38 M
3 Types of surplus weirs Masonry weir + Rockev ground escape
4 Design Discharge 2521 Cft./Sec. or 71.39CUM/Sec
IV Sluice
1 No. of Sluices 3Nos
2 Location of Sluices L/sR/s
3 Maximum Design Discharge
4 Functional or Not functioned
V A. Inspection Detailes
i) Date of inspection 22.2.20
l.Sri D.S.Rajendra Prasad , DEE,ISD,G.D.Nellore@Chittoor,
ii) Name &Designation of 2.Sri K.Bhaskar Reddy,AE,Irrigation section,Penumuru.,
InspectingOfficials 3.Sri M.N.Krishnappa ,ADEN/Pakala, 4.Sri.V.Dhamu
Raju SSE/P.WAY/Chittoor
lii) If the tank quaiiry tor classitication
as RAT Yes
B.Tank Bund
i) IstheToplevel oftheBund
uniform and as per the standards yes
il) Is theTopwidth ofthe Bund as perthe standards Yes
iii) Are theslopes as perthestandards yes
iv)AnyDangerous gulliesor
scoure of the Bund No.
C. Surplus Weir Work In Progress
i) Condtion
ii) Is the length adquate for Design Discharge
iii) Is Danger Level Marked ?
fgjj. /\SGlCtCini UAWUUU i.
D.Condition of the Sluices
IRRlCAl ION riON
E. Any Past History of Breach of the Tankand ifso, details No. \PFNUW1UR
Remarks ; Work in Progress
4_
Signature with Name &Designation Signaturewith Name&Desig<?^i—
of Irrigation Official
DEPUTY EXEGyiE¥£ Ef^GmSEa
Asst. r.ivl. L'ngineer (RRIGN. SUB"DiVlN. G.D.NELLORE @
/ S.C. Railway CHITTOOR.
TiRUPfTI