Page 290 - CRS Engineering
P. 290
Annexure II
PROFORMA FOR SUBMISSION OF R.A.T INSPECTION REPORTS
S.NO. Description Remarks
I General particulars of RAT
Name of the tank VENKATAREDDY CHERUVU
CHCr0026000PAK
District CHnrooR
Name of village & Mandal Chinnakalikiri(V),PenumurufM)
Latitude & Longitude 13° 19' 05" & 79° 09'30"
Afficted Railway Bridge & KM 603 KM
Railway section and between stations SSE PW CTO I
cro PTT-PAk'PTT-PAK
Distance from Railway bndge to weir (along tne course of
Nallah) 200 MTS
Standard Hydraulic Details
II
Catchment Area 0.715 Sq.Miles
Capacity of the Tank 1.31 Mcft
Lowest Bed Level
FullTank Level (FTL) + 00.00 M
Maximum water level (MWL) + 0.6 M
Danger Level (DL)
Top of Bund Level (TBL) 102.10 M
Top width of Bund 3.0 M
Side slopes Front 1.5:1 Rear 2:1
10 Area of submergence at FTL 0.67 M.Sq.M
11 Area of submergence at MWL
12 Are there any tanks in the catchment of these tank ? yes, 1 NO
13 Are these tanks also classifed as RATs' ? yes, 1 NO
14 Names & Details of these tanks 1.ADHI NARAYANAREDDY CHERUVU
III Surplus weir
No. of surplus weirs INos.
Lengths of surplus weirs 13.30 M
Types of surplus weirs NC
Design Discharge 400 Cuseces
IV Sluice
No. of Sluices 2Nos
Location of Sluices 17sR/s
Maximum Design Discharge
Functional or Not
functioned
A. Inspection Detailes
i) Date of inspection 22.2.20
l.Sri D.S.Rajendra Prasad , DEE,ISD,G.D.Nellore@Chittoor,
ii) Name & Designation of 2.Sn K.Bhaskar Reddy,AE,Irrigation section,Penumuru.,
Inspecting Officials 3.Sri M.N.Krishnappa ,ADEN/Pakala, 4.Sri.V.Dhamu
RajuSSE/P.WAY/Chittoor
ill) If the tank qualify for classificationas RAT Yes
B.Tank Bund
i) Is the Iopievel of tne Bund uniform and as per the
standards No
ii) Is the Top widthof the Bund as per the standards No
iii) Are the slopes as per the standards yes
iv) Any Dangerous gullies or scoure of the Bund No.
C. Surplus Weir
I) Condtion Fair
ii) Is the length adquate for Design Discharge yes
III) Is Danger Level Marked ?
D.Condition of the Sluices fair
iginee
Assistant
E. Any Past History of Breach of the Tank and Ifso, details No. CTSON
Remarks : Restoration of Bund is required ( Positive cut offIsrequired)
fENUWlUR.
Signature with Name & Designation Signature with Name &Design^! if
of Railway Offici^l_^
of Irrigation Official
DEPUTY EXECUTIVE ENQimEB/
Asft D vi lyineer
IRRIGN. SUB-DIVIN. G.D.NELLORE @
CHITTOOR.
fvtv '