Page 290 - CRS Engineering
P. 290

Annexure II
                                    PROFORMA FOR SUBMISSION OF R.A.T INSPECTION REPORTS
                  S.NO.                Description                                Remarks
                    I  General particulars of RAT
                       Name of the tank                        VENKATAREDDY CHERUVU
                                                               CHCr0026000PAK
                       District                                CHnrooR
                       Name of village & Mandal                Chinnakalikiri(V),PenumurufM)
                       Latitude & Longitude                    13° 19' 05"  & 79° 09'30"
                       Afficted Railway Bridge & KM            603 KM
                       Railway section and between stations    SSE PW  CTO          I
                                                                     cro PTT-PAk'PTT-PAK
                       Distance from Railway bndge to weir (along tne course of
                       Nallah)                                 200 MTS
                       Standard Hydraulic Details
                   II
                       Catchment Area                          0.715 Sq.Miles
                       Capacity of the Tank                    1.31 Mcft
                       Lowest Bed Level
                       FullTank Level (FTL)                    + 00.00 M
                       Maximum water level (MWL)               + 0.6 M
                       Danger Level (DL)
                       Top of Bund Level (TBL)                   102.10 M
                       Top width of Bund                       3.0 M
                       Side slopes                             Front 1.5:1  Rear 2:1
                   10  Area of submergence at FTL               0.67 M.Sq.M
                   11  Area of submergence at MWL
                   12  Are there any tanks in the catchment of these tank ?  yes, 1 NO
                   13  Are these tanks also classifed as RATs' ?  yes, 1 NO
                   14  Names & Details of these tanks          1.ADHI NARAYANAREDDY CHERUVU
                   III  Surplus weir
                       No. of surplus weirs                    INos.
                       Lengths of surplus weirs                13.30 M
                      Types of surplus weirs                   NC
                       Design Discharge                        400 Cuseces
                   IV  Sluice
                       No. of Sluices                          2Nos
                       Location of Sluices                     17sR/s
                      Maximum Design Discharge
                      Functional or Not
                                                               functioned
                      A. Inspection Detailes
                      i) Date of inspection                    22.2.20
                                                               l.Sri D.S.Rajendra Prasad , DEE,ISD,G.D.Nellore@Chittoor,
                      ii) Name & Designation of                2.Sn K.Bhaskar Reddy,AE,Irrigation section,Penumuru.,
                      Inspecting Officials                     3.Sri M.N.Krishnappa ,ADEN/Pakala,  4.Sri.V.Dhamu
                                                               RajuSSE/P.WAY/Chittoor
                      ill) If the tank qualify for classificationas RAT  Yes
                      B.Tank Bund
                      i) Is the Iopievel of tne Bund uniform and as per the
                      standards                               No
                      ii) Is the Top widthof the Bund as per the standards  No
                      iii) Are the slopes as per the standards  yes
                      iv) Any Dangerous gullies or scoure of the Bund  No.
                      C. Surplus Weir
                      I) Condtion                             Fair
                      ii) Is the length adquate for Design Discharge  yes
                      III) Is Danger Level Marked ?
                      D.Condition of the Sluices              fair
                                                                                                           iginee
                                                                                         Assistant
                      E. Any Past History of Breach of the Tank and Ifso, details  No.                    CTSON
                Remarks : Restoration of Bund is required ( Positive cut offIsrequired)
                                                                                               fENUWlUR.




                            Signature with Name & Designation         Signature with Name &Design^! if
                                   of Railway Offici^l_^
                                                                            of Irrigation Official
                                                                   DEPUTY EXECUTIVE ENQimEB/
                                 Asft D vi   lyineer
                                                                   IRRIGN. SUB-DIVIN. G.D.NELLORE @
                                                                            CHITTOOR.
                                 fvtv    '