Page 287 - CRS Engineering
P. 287

Annexure 11
                                                                     inspection report
                                         DESCRIPTION                                  REMARKS
                 S  NO
                                   General Partlciiliii's of RAI
                  I
                                                                      Srinivasappa Cheruvii
                      ^ame of the Tank
                  1
                                                                      CHCm 007000PAK
                  2   rank ID No.
                                                                      I Chittoor
                  2   District
                                                                      Greamspeta(v) Chittoor(M)
                  3   S'ame of the village & mandal
                                                                       13''-10'-00"&79°-08'-45"
                  4   Latitude & Longitude
                                                                      537 KM 26 / 8-9
                      AffectedRailway Bridge & KM
                                                                      Chittoor-sidampalli
                   6  Railwav Section & between sections
                      Distance from Railway Bridge toweir (along the course ofNallah)  4.00 KM
                   7
                                  Stiindarcl Hydraulic particulars
                  II
                                                                       4.89 sq.km
                   1  Catchment Area
                   2  Capacityof the Tank                              3.88 Mcft.
                   3  Lowest bed level                                 319.90
                   4  Full Tank Level (FTL)                      (M)   323.55
                      Maximum Water Level(MWL)                   (M)   324.15
                   5
                      Danger Level (DL)                                324.15
                   6
                   7  Top ofBund Level (TBL)                    (M)    324.76
                   8  Top width ofbund                          (M)    3.00
                                                                       front 1.5 :18i rear 2:1
                   9  Side slopes
                   10  Area of submergence at FTL
                   11  Area of submergence at MWL
                   12  Are thereany tanksin thecatchmentofthistank     2 Nos
                   13  Are there any tanks also classified as RATs?    No
                      Names & Details of these Tanks
                   14
                                          Surplus weir
                   III
                   1  No of surplus weirs                              one
                       Lenghts ofsurplus weirs                  (M)    19.50
                   2
                   3   Type of surplus weirs                           Masonry
                   4   Design Discharge                                603.18cusec
                   IV                       Sluice
                    1  No of sluices                                   1 No
                   2   Location of sluices
                    3  Maximum Design Discharge
                    4  Functional or not                               closed
                   V   A) Inspection Details
                       1. Date of Inspection                           12-02-2020
                       2. Name & Designationof InspectingOfTicials     1.SriG.Prasanth AEE, Irrigation SectionCtiittoor (M)
                                                                       2.SriP.PratliapaReddy, DEE, ISO QR
                                                                       3.SriIVl.N.Krishnappa, ADEN/Pakala
                                                                       4. SriV.DIiamu Raju,SSE/PWAY, Chittoor

                       3. If the tank qualify for classificationas RAT  Yes
                       B)Tank Bund
                       1.Is the top levelof bund uniform and as per the standards  No
                       2. Is the top width of the bund as per the standards  Yes
                       3. Are the slopes as per standards              Yes
                       4. Any Dngerous gulliesscource of the bund      No
                       C)Surplus Weir
                       1. Condition                                     Repairs requires
                       2. Is the length adequate for Design Discharge  Yes
                       3. Is danger level marked?
                       D)Condition of sluices                          closed
                       E) Any past historyof breach of the tank and Ifso details?  No
                  REMARKS: tank is in good condition


            Assistant'^xecutivi^dfi^r^r          Dj>. Execimi^Engineer

              Irrigation Section,Chittoor.      niR Sob Division,CHITTOOR                               •-2j^
                                                                                        tts                    'a?


                                                                                          FAKaI-P