Page 284 - CRS Engineering
P. 284

r




                                                                                          Annexure II

                                           DESCRIPTION
                  S  NO                                                                 REMARKS
                                     General Particulars of RAT
                    1
                    1  Name of the Tank                                 Gangineni Cheruvu
                    2  Tank ID No.                                      CHCm 002000PAK
                    2  District                                         Chittoor
                       Name of the village & mandal                     Chittoor. CHITTOOR fM)
                    3
                    4  Latitude & Longitude                             13°-12'-20"&79°-08'-35"
                    5  Affected Railway Bridge & KM                     548 KM 40 / 6-8
                    6  Railwav Section & between sections               Chittoor-Siddampalle
                       Distance from Railway Bridge towcir (along the course ofNallah)  1.00 KM
                    7
                                    Standard Hydraulic particulars
                    II
                       Catchment Area                                   5.83 sq.km
                    1
                       Capacity' of the Tank                            9.53 Mcft.
                    2
                       Lowest bed level                                 310.68
                    3
                    4  Full Tank Level (FTL)                       (M)  316.38
                       Maximum Water Level(MWL)                    (M)
                    5                                                   316.88
                    6  Danger Level (DL)                                316.88
                    7  Top of Bund Level (TBL)                    (M)   317.80
                    8  Top width of bund                          (M)   3.70
                    9  Side slopes                                      frontl.5:l&rear2:l
                    10  Area of submergence at FTL
                    11  Area of submergence at MWL
                    12  Are there any tanks in the catchment of this tank  4Nos
                    13  Are there any tanks also classified as RATs?    No
                    14  Names & Details of these Tanks
                    III                    Surplus weir
                    1  No of surplus weirs                              one
                    2  Lenghts of surplus weirs                 (M)     24.30
                    3  Type of surplus weirs                            Masonry
                    4  Design Discharge                                 892 cusecs
                    IV                       Sluice
                    1  No of sluices                                    3.00
                    2  Location of sluices
                    3  Maximum Design Discharge
                    4  Functional or not
                                                                        closed
                    V  A) Inspection Details
                        1. Date of Inspection
                                                                        12-02-2020
                       2. Name & Designation of Inspecting Officials    1.Sri G.Prasanth AEE, Irrigation Section Chittoor (IVI)
                                                                        2.Sri P.Prathapa Reddy, DEE, ISO CTR
                                                                        3.Sri M.N.Krislinappa, ADEN/Pakala
                                                                        4.Sri V.Dhamu Raju, SSE/PWAY, Chittoor
                       3. If the tank qualify for classification as RAT
                                                                        Yes
                       B) Tank Bund
                       1. Is the top level of bund uniform and as per the standards
                                                                        Yes
                       2. Is the top width of the bund as per the standards
                                                                        Yes
                       3. Are the slopes as per standards
                                                                        Yes
                       4. Any Dangerous gullies source of the bund
                                                                        No
                       C) Surplus Weir
                       1. Condition
                                                                        Fair
                       2. Is the length adequate for Design Discharge
                                                                        Yes
                       3. Is danger level marked?
                       D) Condition of sluices
                                                                        closed
                       E)Any past history of breach of the tank and if so details?
                                                                        No
                  REMARKS:tank is in good condition
                                                    fSrytjzjtXaL.
                                                    n^^Exl              gmeet
                 Assistant Executive Engineer ^        S«2t) Dh'i8ion,ceTrroOR
                   Irrigation Section,Chittoor.                                    &oc^t DWt.
   279   280   281   282   283   284   285   286   287   288   289