PROFORMA FOR SUBMISSION OF R.A.T INSPECTION REPORTS Annexure II
S.NO. Description
Remarks
General particulars of RAT
Name of the tank
MANICKYARAYANI CHERUVU
CHCT0027000PAK
District
CHITTOOR
Name of village & Mandal
Chinthapenta (V) Penumur Mandal
Latitude & Longitude 13° 21' 52" & 79° 13' 0"
Afficted Railway Bridge & KM
616 KM 48/8-9
Railway section and between stations SSEPWCro PTT-PAK
Distance trom Railway bridge to weir (along the course of
Nallah)
8.2 KM
Standard Hydraulic Details
.03 Sq.Miles
Capacity of the Tank
3.24Mcft
Lowest Bed Level
344.96 M
FullTank Level (FTL)
+ 347.62 M
Maximum water level (MWL)
+
348.08 M
Danger Level (DL)
Top of Bund Level (TBL)
349.00 M
Top width of Bund 1.20 M
Side slopes
Front 1.5:1 Rear?:i
10 Area of submergence at FTL 1-11 M.Sq.feet 0.103 M.Sg.M
Area of submergence at MWL
12 Are there any tanks In the catchment of these tank ?
yes
13 Are these tanks also classifed as RATs' ?
yes
Surplus weir
No. of surplus weirs
INos.
Lengths of surplus weirs
12.10 M
Types of surplus weirs
Masonry calinoulah
Design Discharge 508Cft./Sec. or 14.39CUM/.Spr
IV Sluice
2Nos
17s R/s
Maximum Design Discharge
functioned
A. Inspection Detailes
Date of inspection
22.2.20
ii) Name & Designation of .1 Pf: f ' DEE,ISD,G.D.Nellore@Chittoor,
Inspecting Officials i'^ M r Reddy,AE,Irrigation section,Penumuru., 4.Sri.V.Dhamu I
i.Sn M.N.Knshnappa ,ADEN/Pakala,
Ra]u SSE/P.WAY/Chittnnr
ill)If the tank qualify for classification as RAT
Yes
B.Tank Bund
Is the Iopievel of the Bund uniform and as per the
standards
No
Is the Top width of the Bundas per the standards No
ill) Are the slopes as per the standards
No
iv) Any Dangerous gullies or scoure of the Bund
No.
Surplus Weir
good
Is the length adquate for Design Discharge
yes
Is Danger Level Marked '
fair
Any Past History of Breachof the Tank and ifso, details
L Assistant Eiig;p-er,
Remarks Restration of Bund repairs is required
IRlllGATlOiN r;.A, IlON
.PENUWIUR.
Signature with Name & Designation Signature with Name &Designate
of Railway Official of
Irrigation Of^u
Assf. Divl. hngfneer deputy EXEcyi'.ys
/ S.C. Railway IRRIGI^. SUB'DIVIN. G.D.NELLORE @
CHITTOOR.
riRURAT!