PROFORMA FOR SUBMISSION OF R.A.T INSPECTION REPORTS           Annexure II
                  S.NO.                 Description
                                                                                   Remarks
                       General particulars of RAT
                       Name of the tank
                                                                MANICKYARAYANI CHERUVU
                                                                CHCT0027000PAK
                       District
                                                                CHITTOOR
                       Name of village & Mandal
                                                                Chinthapenta (V) Penumur Mandal
                       Latitude & Longitude                     13° 21' 52"  & 79° 13' 0"
                       Afficted Railway Bridge & KM
                                                                616 KM 48/8-9
                       Railway section and between stations    SSEPWCro PTT-PAK
                       Distance trom Railway bridge to weir (along the course of
                       Nallah)
                                                               8.2 KM
                       Standard Hydraulic Details
                                                                .03 Sq.Miles
                       Capacity of the Tank
                                                               3.24Mcft
                       Lowest Bed Level
                                                                  344.96 M
                       FullTank Level (FTL)
                                                               + 347.62 M
                       Maximum water level (MWL)
                                                               +
                                                                  348.08 M
                       Danger Level (DL)
                       Top of Bund Level (TBL)
                                                                 349.00 M
                       Top width of Bund                       1.20 M
                       Side slopes
                                                               Front 1.5:1  Rear?:i
                   10  Area of submergence at FTL              1-11 M.Sq.feet 0.103 M.Sg.M
                       Area of submergence at MWL
                   12  Are there any tanks In the catchment of these tank ?
                                                               yes
                   13  Are these tanks also classifed as RATs' ?
                                                               yes
                      Surplus weir
                       No. of surplus weirs
                                                               INos.
                      Lengths of surplus weirs
                                                               12.10 M
                      Types of surplus weirs
                                                               Masonry calinoulah
                      Design Discharge                         508Cft./Sec. or 14.39CUM/.Spr
                  IV  Sluice
                                                              2Nos
                                                              17s R/s
                      Maximum Design Discharge
                                                              functioned
                      A. Inspection Detailes
                        Date of inspection
                                                              22.2.20
                      ii) Name & Designation of                .1 Pf: f       ' DEE,ISD,G.D.Nellore@Chittoor,
                      Inspecting Officials                     i'^ M  r Reddy,AE,Irrigation section,Penumuru., 4.Sri.V.Dhamu I
                                                               i.Sn M.N.Knshnappa ,ADEN/Pakala,
                                                              Ra]u SSE/P.WAY/Chittnnr
                      ill)If the tank qualify for classification as RAT
                                                              Yes
                      B.Tank Bund
                       Is the Iopievel of the Bund uniform and as per the
                      standards
                                                              No
                       Is the Top width of the Bundas per the standards  No
                      ill) Are the slopes as per the standards
                                                              No
                      iv) Any Dangerous gullies or scoure of the Bund
                                                              No.
                       Surplus Weir
                                                              good
                       Is the length adquate for Design Discharge
                                                              yes
                        Is Danger Level Marked '
                                                              fair
                       Any Past History of Breachof the Tank and ifso, details
               L                                                                     Assistant       Eiig;p-er,
               Remarks Restration of Bund repairs is required
                                                                                      IRlllGATlOiN r;.A, IlON
                                                                                          .PENUWIUR.

                           Signature with Name & Designation  Signature with Name &Designate
                                  of Railway Official                                                  of
                                                                            Irrigation Of^u
                              Assf. Divl. hngfneer           deputy EXEcyi'.ys
                                     / S.C. Railway         IRRIGI^. SUB'DIVIN. G.D.NELLORE @
                                                                      CHITTOOR.
                                       riRURAT!