Page 5 - Bernardon Proposal-Progressive New Homes
P. 5

www.bernardon.com











               Project Understanding



               The proposed site is located along the E. Johnson    services, we will provide a complete review and
               Highway between Dekalb Pike and Arch Street in       identify needed modifications and additions to the
               Norristown, Montgomery County, Pennsylvania.         previously completed plans.
               The Project will consist of four (4) new market-rate
               rental apartment buildings and a new clubhouse       The clubhouse will be a single-story building of
               as shown on the latest iteration of the Land         approximately 2,500 square feet connected to an
               Development Plan prepared by Irick Eberhardt &       outdoor pool and patio space that is approximately

               Mientus, Inc. dated July 12, 2022 (attached hereto   6,500 square feet.
               as Exhibit “A”).
                                                                    This proposal includes design within the footprint
               Each residential building will be four (4) stories   of each building, including attached balconies
               above grade without basements or crawl spaces.       and canopies.  We assume there will not be any
               The  overall  residential  program  will  include  a   steps within any of the building footprints and any
               total of 200 units and approximately 203,000         grade changes will be accommodated outside
               gross square feet.  We will use the unit layouts,    the building footprint with stairs and ramps.  We
               attached  hereto as Exhibit B, for initial design    understand all design work outside the building
               and incorporate any changes necessary for code       and pool deck footprints will be by others,
               compliance, accessibility requirements, structural   including stormwater management, grading,
               coordination, and space for mechanical, electrical,   utilities, lighting, site accessibility up to building
               plumbing, and fire protection (MEPFP) systems.       entrances, landscape, sidewalks, parking, and
               Based on the initial review, space will need to      retaining walls.
               be allocated for building electrical, water, and
               sprinkler systems, electrical meters, mechanical     The buildings will be fully sprinklered, Type VA
               shafts, elevator machine rooms, and low voltage      combustible  wood  construction  with  one-hour
               pathways which will affect the final unit layouts.   fire-rated interior and exterior bearing walls,
                                                                    floors, and roofs with fire-rated shafts and
               Based on the provided floor plans and unit           stairways.  The foundation system is anticipated
               layouts (attached hereto as Exhibit “B”), there are   to be concrete spread footings and foundation
               currently six (6) different one-bedroom unit types   walls with a ground floor slab on grade without
               and five (5) different two-bedroom unit types for    a crawl space or basement.  Upper floors will
               a total of eleven (11) typical unit plans.  We will   be prefabricated wood trusses with plywood
               also document four (4) additional Type A units       subfloors and gypcrete topping.  Roofs will
               and work with you to determine where these are       consist of prefabricated wood gable trusses.
               located.                                             Miscellaneous steel may be required for larger
                                                                    spans.
               In a review of the previously prepared plans, we
               believe there are possible inadequacies with         The mechanical systems will be individual vertical
               possible code compliancy of the unit designs as      package units with exterior louvers at each unit
               well as insufficient spaces for building mechanical   with ducting to living spaces based on the current
               and electrical systems.  As part of our scope of     unit plans.  Gas, electric, and heat pump options



               BERNARDON | Response to Request for Proposal
               Progressive New Homes | Kennedy Kenrick Residential Development | August 12, 2022          Page 1