Page 121 - QR CIMAR LASER SCREED
P. 121

12 Troubleshooting

Alerts and Message  Alert                Symptom                   Possible causes and solutions
Screens
                             007746_001  Low Battery indication The batteries are low. Replace the alkaline

                                         on the display.           batteries or recharge the Li-Ion battery

                                                                   pack. Refer to "9 Batteries".

                                         Elevation (H.I.) Alert    The Rugby has been bumped or tripod was
                                         The Elevation (H.I.)      moved. Turn off Rugby to stop alert, check
                                         Alert screen is shown     the height of the laser before beginning to
                                         and the audio beeps.      work again. Allow Rugby to relevel and check
                                         (Level position)          the height of the laser.
                                                                   After 2 minutes in the alert condition, the
                     007610_001                                    unit will shut off automatically.
                    007747_001
                    007748_001           Servo Limit Alert         The Rugby is tipped too far to reach a level
                    007749_001           The Servo Limit Alert     position. Relevel the Rugby within the
                     007627_001          screen is shown.          6 degree self-levelling range.
                     007750_001                                    After 2 minutes in the alert condition, the
                    007751_001                                     unit will shut off automatically.

                                         Tilt Alert                The Rugby is tipped more than 45° from
                                         The Tilt Alert screen is  level.
                                         shown.                    After 2 minutes in the alert condition, the
                                                                   unit will shut off automatically.

                                         Temperature Alert         The Rugby is in an environment where it

                                         The Temperature Alert cannot operate without damaging the laser

                                         screen is shown.          diode, for example being exposed to the

                                                                   heat from direct sunlight. Shade the Rugby

                                                                   from the sun.

                                                                   After 2 minutes in the alert condition, the

                                                                   unit will shut off automatically.

                                         Temperature Check         The Rugby has detected a change in temper-
                                                                   ature of 5°C and is checking the level posi-
                                         The Temperature
                                         Check Alert screen is     tion.
                                         shown.                              Wait until procedure is complete.
                                                                             Refer to " Temperature Sensitivity
                                                                             Settings" for changing the setting
                                                                             between 5°C and 2°C.

                                         Negative grade entry is The negative grade function is disabled.

                                         not possible.             Only positive grade can be entered in the

                                                                   Rugby. To enter negative grade, enable the

                                                                   negative grade function. Refer to " Negative

                                                                   Grade - Enable/Disable".

                                         The “empty battery”       The Rugby has reached a low battery condi-
                                         icon flashes.             tion and changes the head speed to 7rps. If
                                                                   the Rod Eye detects the Rugby rotating at

                                                                   7 rps, it displays a small flashing Rugby.
                                                                             Check the battery of the Rugby.

Rugby 870/880, Troubleshooting                                                                               61