Page 119 - QR CIMAR LASER SCREED
P. 119
Calibrating step-by- Step 1 - Align the X-axis (X+) towards the Rod Eye 180
step
30 m (100 ft)
X+
007844_001 Description
Screen Indication While aligning, the Rugby displays an
“hour glass” screen.
When the axis is successfully aligned, a
“ROTATE” screen is displayed on which
the first axis shows “OK”.
007736_001 007741_001
Step 2 - Rotate the Rugby 90° and align Y-axis (Y-) towards the Rod Eye 180
30 m (100 ft)
Y—
007845_001 Description
Screen Indication While aligning, the Rugby displays an
“hour glass” screen.
When the axis is successfully aligned, a
“ROTATE” screen is displayed on which
the second axis shows “OK”.
007737_001 007742_001
Step 3 - Rotate the Rugby 90° and align X-axis (X-) towards the Rod Eye 180
30 m (100 ft)
X—
007846_001 Description
Screen Indication While aligning, the Rugby displays an
“hour glass” screen.
When the axis is successfully aligned, a
“ROTATE” screen is displayed on which
the third axis shows “OK”.
007739_001 007743_001
Rugby 870/880, Semi-Automatic Calibration 59