Calibrating step-by- Step 1 - Align the X-axis (X+) towards the Rod Eye 180
step

                                                                                                   30 m (100 ft)
                                                                                                          X+

007844_001                                                Description

Screen Indication                                         While aligning, the Rugby displays an
                                                          “hour glass” screen.
                                                          When the axis is successfully aligned, a
                                                          “ROTATE” screen is displayed on which
                                                          the first axis shows “OK”.

007736_001         007741_001

Step 2 - Rotate the Rugby 90° and align Y-axis (Y-) towards the Rod Eye 180

                                           30 m (100 ft)
                                                  Y—

007845_001                                                Description

Screen Indication                                         While aligning, the Rugby displays an
                                                          “hour glass” screen.
                                                          When the axis is successfully aligned, a
                                                          “ROTATE” screen is displayed on which
                                                          the second axis shows “OK”.

007737_001         007742_001

Step 3 - Rotate the Rugby 90° and align X-axis (X-) towards the Rod Eye 180

                                           30 m (100 ft)
                                                  X—

007846_001                                                Description

Screen Indication                                         While aligning, the Rugby displays an
                                                          “hour glass” screen.
                                                          When the axis is successfully aligned, a
                                                          “ROTATE” screen is displayed on which
                                                          the third axis shows “OK”.

007739_001         007743_001

Rugby 870/880, Semi-Automatic Calibration                                                                         59