Fire Extinguishers











































                      Fired Containers


                  If waste is tipped from a container that appears to be smouldering or on fire you must
                  firstly inform the site manager/foreman. This must be extinguished and separated from
                  the other waste on site to stop it from spreading.

                      Possible Fire Scenarios


                  The following is a list of instances that are most likely to cause problems in Transfer
                  Stations :-
                    A.  A load arrives on site which is visibly on fire

                    •  The load must tipped in an area away from the normal tipping area (the middle of
                       the  yard  is  advisable)  or  into  a  designated  area  and  away  from  any  fuels,
                       machinery, site personnel or visitors.
                    •  During tipping, fire hoses and fire extinguishers must be ready to spray the load
                    •  Once tipped, the vehicle must be moved to a safe distance from the fire.
                    •  The load must be thoroughly soaked and spread out using the grab loader to
                       ensure  the  fire  is  fully  extinguished.  Fire  extinguishers  must  be  at  hand  to
                       extinguish any materials that cannot be extinguished with water.
                    •  The site Manager/foreman must attend the load to assess whether the fire is fully
                       extinguished and to what extent the load has cooled.
                    •  The load may only join the waste stream after it is fully cooled.