Page 12 - 2020 7th St Presentation
P. 12
L:\21-133 Toscana 2020 7th St S\ALD-Dwgs\21-133.dwg, 9/12/2021 10:27:35 PM, AutoCAD PDF (General Documentation).pc3
Drain Detail Bubble Up Drain Detail Downspout Detail
A1 Scale: 1" = 1'-0" A2 Scale: 1" = 1'-0" A3 Scale: NTS
L:\21-133 Toscana 2020 7th St S\ALD-Dwgs\21-133.dwg, Plotted on 9/12/2021 10:27:36 PM by Christian Andrea
NDS 6" Atrium Polyethylene
Grate w/ UV Inhibitor NDS Polyethylene w/ U.V. Inhibitor
NDS #66 - 6" Sewer Turf NDS 12" Square Catch Basin
Stone & Drain Pipe Riser
(Length as Required) Building Facade
Grade Downspout
3" (Copper, Aluminum LANDSCAPE ARCHITECTURE
Filter
Fabric or PVC)
Filter Fabric 2780 S. Horseshoe Drive Suite 5
Drill 1" Holes in Drill 1" Holes in Cut Hole in Grate to Match Naples, FL 34104
NDS 9" Square Catch Basin
side of Box (12) side of Box (20) Opening of Downspout Pipe (239) 430-1661
1" Air Gap
Drill Holes in 6" PVC Pipe Stone Design@ALDinc.net
Bottom of Box Filter Fabric
8" No 57 Stone, 8" Depth License LC26000259
Filter Fabric 6" Drain Pipe From Bottom of Basin Drill 1" Holes in NDS #66 - 6" Sewer
side of Box (12) & Drain Pipe Riser Christian Andrea
8" No 57 Stone, 8" Depth (Length as Required)
From Bottom of Basin Drill 1" Holes in
bottom of Box
6" Drain Pipe
Filter Fabric
NDS 9" Square Catch Basin
No 57 Stone
Drill 1" Holes in License No. 1178
bottom of Box
Copyright Architectural Land Design ©
Concrete Drive Detail Patio Paver Detail Wood Deck Detail
B Scale: 1/2" = 1'-0" C Scale: 1/2" = 1'-0" D Scale: 1/2" = 1'-0"
All deck to be screwed in place with
3" stainless steel screws
1.5" x6" Trex Decking (Installed w/ hidden deck
fasteners and slotted decking)
1' 3" x 8" Marine Grade Joists
Mulch (planter beds only)
Stone Deck Installed 16" O.C.
Aluminum Border Edging
(where joints are adjacent to edge of drive) Miter Cut 3" x 8" Marine Grade Beams
Scoured Expansion Joints in Concrete 6" Thick Exposed Poured Concrete 1" +\- Thick Mortar bed
(See plan for Spacing) (Optional Schluter Drain Material)
Slab w/ Aggregate Finish
4" Concrete Slab
6" Turf Strips 1' 6x6, 10ga. Welded Wire Mesh
4"
or Fibercrete
6" Turf Strips
Rebar #5 Compacted Subgrade 95% 12" #57 Stone
Optimun Proctor Density (beneath Deck for Drainage
Scoured Expansion Joints in Concrete 12x24 Stone Border System to be installed)
Compacted Subgrade Brookstone Border
(See plan for Spacing) (where pavers are adjacent to the planting beds) Decking (Confirm Material Toscana Residence 2020 7th St. S. City of Naples, FL SITE DETAILS
95% Optimun Proctor Density
Set stone on concrete Selection w/ owner)
Mulch (planter beds only)
authorization. Any deviations or inaccuracies need to be brought to the attention of the Owner immediately. * All base information has been provided by others, verification of setbacks, property lines, etc. need to be provided by others. * It is the Contractors responsibility to verify that he has the most current plan. * Contractor shall not scale from plan, use dimensions only. * These plans are the property of Architectural Land Design and may not be used or reproduced without This Document contains information proprietory to ARCHITECTURAL LAND DESIGN and no part of this drawing shall be reproduced or disclosed to others or used for any purpose other than that for which it was furnished, without prior written permission from ARCHITECTURAL LAND DESIGN. Exposed Concrete with 12"x18" Staggered Running Bond Pattern
Minimum 6" Thick Concrete Pads
Aggregate or Shell Finish
Drawing Date: IS 07.09.21
Scale: As Noted
21-133
File Name: 21-133.dwg
Architectural Information Provided By:
Company Name: ----
File Name: ----
Date: ----
Site Information Provided By:
Company Name: ----
File Name: ----
Date: ----
1.4
Contractor to verify property lines and setbacks before construction.
Contractor must have property lines staked and located,
and must verify plan dimensions and field conditions are consistent.
Any Inconsistencies w/ these plans need to be reported to ALD and the Owner.
Contractor shall verify that he has the most up to date plans, and that they have
Contractor shall verify that he has the most up to date plans, and that they have been approved and accepted by the Owner before commencing construction. been approved and accepted by the Owner before commencing construction.