Page 48 - Foton Workshop Manual - Auman EST-M
P. 48

IN - 42                      Introduction - How to remove the vehicle faults


                                                        b. Attentions for connector operation
                                                        Adopt a blower or similar tool to heat the part possible to
                                                        cause the fault and check whether the fault occurs.
                                                        ● In case of removing the connector with latch, squeeze the
                                                        connector slightly in jointing direction, and then press down
                                                        its buckle lightly to open the latch.
                                                        ●  In  case  of  removing  the  connector,  be  sure  to  hold  the
                                                        connector, and don’t pull the harness.
                                                        ● In case of connecting the connector, be sure to check the
                                                        connector for deformations, damages or pin missing.
                                                        ● In case of connecting the connector with latch, be sure to
                                                        hear “clicking” sound to ensure its firm connection.
                                                        ● In case of checking the connector with a  multimeter, be
                                                        sure  to  check  the  back  of  connector  (harness  side)  with  a
                                                        micro probe.
                                                                                Caution
                                                         ●  Since  the  waterproof  connector  can’t  check  from  its
                                                        back,  please  connect  the  auxiliary  harness  before  the
                                                        check.
                                                        ● Move the probe with care, and don’t damage any pin
                                                        of  connector.  Confirm  the  key  points  for  connector
                                                        check.

                                                        c. Confirm the key points for connector check.
                                       Loosening of
                                       turned edge      Check the following points while connecting the connector:
                                                        ●  Hold  the  connector,  and  check  its  insertion  and  locking
                                                        conditions (i.e. bonding conditions).
                                  Wire core
                                                        Check  the  following  points  in  case  of  disconnecting  the
                                           Bent pin
                                                        connector:
                                                        ●  Pull  the  harness  lightly,  and  check  its  pins  for  missing,
                               Light pulling
                                                        bending or center harness for fracture.

                                                        ●  Visually  check  the  connector  for  rusting,  inclusion  of
                                                        metal chippings, water entry, or check the pins for bending,
                                                        rusting, inclusion of foreign substances or deformations.

                                                        Check the contact pressure of pin:
                                                        ●  Prepare  a  male  plug,  insert  it  into  the  socket  plug,  and
                                                        check its bonding conditions and sliding resistance.
                                                                                Caution
                                                        In case of checking the gold-plated socket plug, be sure
                                                        to adopt the gold-plated male plug.
                              Same material






                                                          IN-042
   43   44   45   46   47   48   49   50   51   52   53