Page 1100 - Workshop Manual - Aumark (BJ1051)
P. 1100
51-8
Heater and air conditioner- heater and air conditioner
5. no hot air or hot air is not enough
symptom Suspect area Reference
1. air blower (damaged) Chapter 51 heater and air
conditioner-air blower, replacement
2. air blower relay (damaged) -
3. hot air duct (detached) Chapter 51 heater and air conditioner-
air flue, replacement
4. temperature control ventilation Chapter 51 heater and air conditioner-
door (damaged) hot air water tank, replacement
Hot air is not provided.
5. water control valve (damaged) Chapter 51 heater and air conditioner-
hot air water pipe, replacement
6. control panel cable (detached) Chapter 73 instrument
panel/combination meter/cigar lighter-
instrument panel, replacement
1. coolant liquid (not enough or -
blocked)
2. heater core fin (distorted) Chapter 51 heater and air conditioner-
hot air water tank, replacement
Hot air is not enough
3. heater pipeline (filth accumulated
or air in it) Chapter 51 heater and air conditioner-
hot air water pipe, replacement
51
Page 1100