Page 1126 - Workshop Manual - Aumark (BJ1051)
P. 1126
51-34
Heater and AC-Refrigerant oil
z Malfunction of expansion valve
Condition: effect of
refrigeration is
insufficient
Phenomenon Possible reasons Diagnosis Measures
The pressures of low There is problem on There is excessive Check and replace
pressure side and high expansion valve. refrigerant in low pressure expansion valve.
pressure side are high. pipe.
There is frost or large The opening of expansion
quantity of dew on the valve is too big.
pipeline of low pressure
side.
z Malfunction of compressor
Condition: it is
not refrigerated
51
Phenomenon Possible reasons Diagnosis Measures
The pressures of low Inside of compressor is Malfunction of compressor. Repair or replace the
pressure side is too high leaking. It is leaking on the position compressor
The pressure of high of damaged valve or
pressure side is too low. moving part.
Page 1126