Page 1147 - Workshop Manual - Aumark (BJ1051)
P. 1147

51-55
                                                     Heater and AC-Evaporator

                                                                (b).    Fasten 3 bolts and assemble fuse box.










               16.     Assemble instrument panel installation  cross member welding assembly (refer to
                      “Chapter 51 Heater and AC-Heater, Replacement”).
               17.     Assemble instrument panel (refer to “Chapter 73 Instrument panel/combined
                      meters/cigar liter-Instrument panel, Replacement).
                                                                18.     Connect AC pipe
                                                                (a)     Fasten connection nut of AC pipe to
                                                                        connect AC pipe.
                                                                        Torque: 15 ± 5 N•m  (Φ9 aluminum
                                                                        pipe)
                                                                        Torque: 23 ± 3 N•m  (Φ12 aluminum
                                                                        pipe)
                                                                        Torque:  :30 N•m  (Φ16 aluminum
                                                                        pipe)
                                                                (b).    Fasten bolt and install the AC pipe
                                                                        clamp.
               19.     Assemble front cover assembly (refer to “Chapter 77 Inner/outer trimming
                      parts-Front cover assembly, Replacement”)                                                     51
               20.     Fill in refrigerant (refer to “Chapter 51 Heater and AC-Refrigerant, Replacement)
               21.     Run engine to normal working temperature
               22.     Check if the refrigerant is leaking (refer to “Chapter 51 Heater and AC-Refrigerant,
                      Inspection”)