Page 1302 - Workshop Manual - Aumark (BJ1051)
P. 1302

61-30
                                             Circuit-System circuit diagram

          AC runs state
              AC starts to run when AC switch is at closed position and the blower switch is at LO position
          ·  Running state of blower
              Current goes through electromagnetic coil of heater relay R13 to the pin No. 12 of blower switch; to the pin No. 9
              of blower switch to ground through blower switch; electromagnetic coil generates magnetic field and contact of
              relay R13 closes; current goes through the contact of heater relay R13 to the pin No. 1 of blower; to pin No. 2 of
              blower and pin No. 9 of speed regulating resistor through blower motor; to pin No. 4 of speed regulating resistor
              and  pin  No.  12 of  blower switch through speed regulating  resistor; to pin  No. 9 of  blower to ground through
              blower switch, and the blower starts to run at low speed.
              Current goes through blower motor to pin No. 2 of blower and pin No. 1 of speed regulating resistor when blower
              switch is at M1 position; to pin No. 2 of speed regulating resistor and pin No. 1 of blower switch through speed
              regulating resistor; to pin No. 9 of blower to ground through blower switch.
              Current goes through blower motor to the pin No. 2 of blower and pin No. 1 of speed regulating resistor when
              blower switch is at M2 position; to pin No. 3 of speed regulating resistor and pin No. 8 of blower switch through
              speed regulating resistor; to pin No. 9 of blower to ground through blower switch.
              Current goes through blower motor to pin No. 2 of blower and pin No. 11 of blower switch when blower switch is
              at HI position; to pin No. 9 of blower to ground through blower switch.
          ·  Compressor runs state
              From pin No. 11 of signal amplifier to pin No. 5 of AC switch; through AC switch to pin No. 6 of AC switch and
              pin No. 12 of blower switch; to pin No. 9 of blower through blower switch; signal amplifier confirms the running
              signal of AC and controls the electromagnetic coil of the electromagnetic clutch relay R15 to ground through pin
              No. 7 of signal amplifier; electromagnetic coil generates magnetic field and contacts of relay R15 is closed; current
              goes through the contacts of electromagnetic clutch relay R15 to the pin No. 27 of engine control unit; and engine
              control unit will control the electromagnetic coil of AC main relay R36 after it receives the signal; engine control
              unit is grounding and electromagnetic coil generates magnetic field; contacts of relay R36 close and current goes
              through the contact of AC main relay R36 to the pin No. 1 of compressor electromagnetic clutch; to the external
              housing to ground through the electromagnetic coil of clutch; compressor starts to run.
              AC pressure switch will be at disconnection state when there is abnormal of high voltage or low voltage inside of
              AC system; electromagnetic clutch relay R15 will be failed and compressor stops running.
          ·  Condenser fan runs state
              Current goes through the contacts of AC main relay R36 to electromagnetic oil of speed regulating relay R17 of
              condenser to ground when compressor is at working state; electromagnetic coil is electrified to produce magnetic
              field; contacts of speed regulating relay R17 of condenser close and current goes through the contacts of speed
              regulating relay R17 of condenser to pin No. 1 of condenser fan; to pin No. 2 of condenser fan to ground through
              inside resistor; condenser fan starts to ran at low speed.
              Electromagnetic oil of condenser relay R16 will fail  when middle voltage switch  is turned on;  contacts  of
              condenser relay R16 will return (30 and 87a is connected); pin No. 4 of condenser fan is grounded through the
              contact of condenser relay R16; condenser fan starts to ran at high speed.

                 :Part position

                           Reference wire                  Reference wire                   Reference wire
               S/N                              S/N                              S/N
                                harness                          harness                         harness
              B001           Body wire         B042           Body wire         C003          Chassis wire

              B005           Body wire         B043           Body wire         C006          Chassis wire
              B007           Body wire         B050           Body wire         C033          Chassis wire
              B008           Body wire         C002          Chassis wire       C051          Chassis wire
   61
               : position of the insert part
            S/N        S/N                    Reference wire harness (position of the insert parts)
            B103      C101              Body wire and chassis wire (middle of the first cross member of frame)
            B105      C105              Body wire and chassis wire (middle of the first cross member of frame)
            C103      B107              Body wire and chassis wire (middle of the first cross member of frame)






                                                                                                        Page 1302