Page 267 - Workshop Manual - Aumark (BJ1051)
P. 267

04-123
                                                       Diagnosis- illumination
               Diagnostic Procedure

               1.     Checking high beam relays


                                                                (a)     Check high beam relay R30 and R31.
                                                                     Standard values:

                                                                                   Use a multimeter   Specified
                                                                     Condition
                                                                                    to connect pins    value
                                                                      Normal             1 - 2       Continuity
                                                                    Apply supply         3 - 5       Continuity
                                                                   voltage between
                                                                    pins 1 and 2.
                                                                                                                   04

               Are check results normal?
               Yes >   Repair or replace harnesses.
               No >    Replace high beam relays.