Page 277 - Workshop Manual - Aumark (BJ1051)
P. 277

04-133
                                                       Diagnosis- illumination
               Diagnostic Procedure

               1.     Checking high beam relay


                                                                 (a)     Check high beam relay R30/R31.

                                                                      Standard values:



                                                                                   Use a multimeter   Specified
                                                                     Condition
                                                                                    to connect pins    value
                                                                      Normal             1 - 2       Continuity
                                                                    Apply supply         3 - 5       Continuity    04
                                                                   voltage between
                                                                    pins 1 and 2.


               Are check results normal?
               Yes >   Repair or replace harness.
               No >    Replace high beam relay.
























































                                                                                                         Page 277