Page 438 - Workshop Manual - Aumark (BJ1051)
P. 438
04-294
Diagnosis-Power Windows
(c) Use a multimeter to measure resistance to ground of fuse F4 (20A).
Resistance: >1MΩ
Is check result normal?
Yes > Go to step 3.
No > Repair lines to ground short between fuse F4 (20A) to connector pin 3 of left front door
control switch E003 and connector pin 5 of right front door electric glass switch.
3. Checking left front door control switch
4
(a) Measure resistances according to the values listed in the following table.
Use a multimeter to Switch status Resistance
connect terminals
3 - 10 Left front window lift ≤ 2 Ω
6 - 9 Left front window lift ≤ 2 Ω
6 - 9 - 10 Left front window still (i.e. switch in natural position) ≤ 2 Ω
6 - 10 Left front window drop ≤ 2 Ω
3 - 9 Left front window drop ≤ 2 Ω
3 - 4 Right front window lift ≤ 2 Ω
2 - 6 Right front window lift ≤ 2 Ω
2 - 4 - 6 Right front window still (i.e. switch in natural position) ≤ 2 Ω
4 - 6 Right front window drop ≤ 2 Ω
2 - 3 Right front window drop ≤ 2 Ω
2 - 9 Window lock switch depressed > 1MΩ
4 - 9 Window lock switch depressed > 1MΩ
Are check results normal?
Yes > Go to step 4.
No > Replace left front door control switch.
Page 438