Diagnosis- combination meter
4. Checking for low pressure warning light signal circuit open
(a) Use a multimeter to measure voltage to
ground of connector pin 18 of
combination meter B032.
Voltage: battery voltage
04
Is check result normal?
Yes > Repair signal line open between connector pins 1 of low pressure alarms C027 and C037
and connector pin 18 of combination meter B032.
No > Replace combination meter assembly.