                                                    Diagnosis- combination meter

               4.     Checking for low pressure warning light signal circuit open

                                                                (a)     Use a multimeter to measure voltage to
                                                                        ground of connector pin 18 of
                                                                        combination meter B032.
                                                                        Voltage: battery voltage









   04
               Is check result normal?
               Yes >   Repair signal line open between connector pins 1 of low pressure alarms C027 and C037
                      and connector pin 18 of combination meter B032.
               No >    Replace combination meter assembly.