Page 506 - Workshop Manual - Aumark (BJ1051)
P. 506
04-362
Diagnosis-Power Windows
4. Checking for oil pressure indicator light signal circuit open
(a) Use a multimeter to measure voltage to
ground of connector pin 10 of
combination meter B034.
Voltage: battery voltage
Is check result normal?
4 Yes > Repair signal line open between connector pin 1 of oil pressure alarm switch C040 and
connector pin 10 of combination meter B034.
No > Replace combination meter assembly.