Page 504 - Workshop Manual - Aumark (BJ1051)
P. 504

04-360
                                                      Diagnosis-Power Windows

                                                                (b)     Disconnect connector of oil pressure
                                                                        alarm switch.


















   4



               (c)    Ignition switch: ON.
               Check if oil pressure indicator light goes out.
               Yes >   Replace oil pressure alarm switch.
               No >    Go to step 2.
               2.     Checking for oil pressure indicator light signal circuit short
               (a)    Ignition switch: OFF.
                                                                (b)     Disconnect connector of combination
                                                                        meter B034.












                                                                (c)     Use a multimeter to measure resistance
                                                                        to ground of connector pin 1 of oil
                                                                        pressure alarm switch C040.
                                                                        Resistance: >1MΩ









               Is check result normal?
               Yes >   Replace combination meter assembly.
               No >    Repair signal line to ground short between connector pin 1 of oil pressure alarm switch
                      C040 and connector pin 10 of combination meter B034.










                                                                                                         Page 504
   499   500   501   502   503   504   505   506   507   508   509