Page 504 - Workshop Manual - Aumark (BJ1051)
P. 504
04-360
Diagnosis-Power Windows
(b) Disconnect connector of oil pressure
alarm switch.
4
(c) Ignition switch: ON.
Check if oil pressure indicator light goes out.
Yes > Replace oil pressure alarm switch.
No > Go to step 2.
2. Checking for oil pressure indicator light signal circuit short
(a) Ignition switch: OFF.
(b) Disconnect connector of combination
meter B034.
(c) Use a multimeter to measure resistance
to ground of connector pin 1 of oil
pressure alarm switch C040.
Resistance: >1MΩ
Is check result normal?
Yes > Replace combination meter assembly.
No > Repair signal line to ground short between connector pin 1 of oil pressure alarm switch
C040 and connector pin 10 of combination meter B034.
Page 504