Page 151 - booklet draft
P. 151

iii)    ROOT  CAUSE  ANALYSIS  OF  WATER  ENTRY  THROUGH  VIKRANTH

                    ENGINEERING OCB FILTERS DUE TO MANUFACTURING DEFECT

                    M/s Vikrant Engineering Works/Kolkata make Oil cooling Blower Filters
                    provided  in  OCU  units in  three  phase  locomotives.  Rain  water  is
                    draining  from  the  roof  OCB  filter  directly  on  the  radiator  instead  of
                    draining mechanism (duct pipes). It was noticed that the venturi filter
                    is  not  having  any  mouth  piece  in  addition  to Vortex  generator  and
                    resulting in  rain  water and  dust  particles  are  falling directly in  to the
                    OCB duct and resulting in failure of OCB motor due to moisture. Shed

                    has carried out a cyclic check in 66 Locos (132 cab sets) of these 68
                    cab sets were found defective. Firm has agreed it as a manufacturing
                    defect and agreed to make good all the defective filters in the shed.
                    50 cab  sets  were  replaced by  firm and  balance  18 cab  sets  to  be
                    replaced.