ii)     ROOT CAUSE ANALYSIS FOR FAILURES OF  INPUT CHOKES DUE TO WATER

                    ENTRY IN M/S SIEMENS HLCs

                    ELS/LGD has advised about rain water leakage through Outlet Louvers
                    of  Hotel  load  converters  into  the  machine  room due  to  improper
                    design of Outlet louvers. Rain water is seeping through outlet louvers
                    and stagnating below hotel load converters and resulting into failure
                    of  input  chokes. M/s  Siemens  has  accepted  the  observations  of
                    ELS/LGD and replaced all old design filters with modified arrangement
                    to  prevent  failure  of  input  chokes  and  improve  reliability  of

                    locomotives.
                         OLD DESIGN LOUVER                        NEW DESIGN LOUVER