 Compliant Cables and Accessories                                                      25567_eyal-Y-MK1-837 - 25567_pnim_y-mk1-837_eyal.1.1 | 7 - A | 18-06-11 | 09:03:44 | SR:-- | Cyan

 Use of non-original cables or accessories may result in increased   Guidance and Manufacturer's declaration - Electromagnetic Immunity
 emissions or decreased immunity performance of the product.
                     ®
           The ProPex  II is intended for use in the electromagnetic environment specified
                                                 ®
           below. The customer or the user of the ProPex  II should assure that it is used in
 The table below lists cables and accessories for which the manufacturer   such an environment.
 claims EMC compliance:  Immunity test  IEC 60601-1-2  Compliance level  Electromagnetic
                           Test level                       environment - guidance
 Description  Details                                      Floors should be wood,
           Electrostatic                                   concrete or ceramic tile.
 Measurement cable  Original only.  discharge   ± 8 kV contact  ± 8 kV contact  If floors are covered with
 Accessories:  (ESD) IEC   ± 15 kV air   ± 15 kV air       synthetic material, the
           61000-4-2                                       relative humidity should
 Lip Clip  Original only.
                                                           be at least 30%.
 Connection Hook  Original only.
                                                           Mains power quality
 Connection Fork  Original only.  ± 2 kV for power         should be that of a typical
 Original Switching charger only:  Electrical fast   supply lines  ± 2 kV for power   public low-voltage power
 Charger  Input: 100 - 240 VAC / ~ 50-60 Hz  transients /   supply lines  supply network that
 Output: 6 VDC ± 5%, 1000 mA  bursts IEC   ± 1 kV for input/  supplies buildings used
           61000-4-4                     Not applicable    for domestic purposes,
                        output lines
                                                           commercial or hospital,
                                                           clinic environment
                                                           Mains power quality
                                                           should be that of a typical
                        ± 1 kV Line-to-line  ± 1 kV Line-to-line  public low-voltage power
           Surges IEC                                      supply network that
           61000-4-5    ± 2 kV Line-to-  ± 2 kV Line-to-   supplies buildings used
                        ground           ground            for domestic purposes,
                                                           commercial or hospital,
                                                           clinic environment


















 170/184  B EU PIIS DFU PRT / Rev.04 / 02-2018 (Old ZF 1902127.X)  B EU PIIS DFU PRT / Rev.04 / 02-2018 (Old ZF 1902127.X)  179/184