                                                        Mains power quality                      Appendix 1
 25567_eyal-Y-MK1-837 - 25567_pnim_y-mk1-837_eyal.1.1 | 7 - B | 18-06-11 | 09:03:44 | SR:-- | Magenta
                                                        should be that of a typical
 25567_eyal-Y-MK1-837 - 25567_pnim_y-mk1-837_eyal.1.1 | 7 - B | 18-06-11 | 09:03:44 | SR:-- | Yellow
 #25567_eyal-Y-MK1-837 - 25567_pnim_y-mk1-837_eyal.1.1 | 7 - B | 18-06-11 | 09:03:44 | SR:-- | Black
 25567_eyal-Y-MK1-837 - 25567_pnim_y-mk1-837_eyal.1.1 | 7 - B | 18-06-11 | 09:03:44 | SR:-- | Cyan
        Voltage dips  0% U ; 0.5 cycle  0% U ; 0.5 cycle  public low-voltage power                       ELECTROMAGNETIC COMPATIBILITY
                         T
                                           T
                                                        supply network that
                                                                                                         EMC according to IEC 60601-1-2 ed.3
                                                        supplies buildings used
                                                        for domestic purposes,
                     0% U ; 1 cycle  0% U ; 1 cycle   commercial or hospital,                          Changes or modifications to this product not expressly approved by the
                         T
                                           T
                     and             and
        Voltage                                         clinical environment. If                         manufacturer may result in increased emissions or decreased immunity
                                            T
                          T
        interruptions  70% U ; 25/30   70% U ; 25/30    the user of the                                  performance of the product and could cause EMC issues with this or
                     cycles           cycles            ProPex  II requires                              other equipment. This product is designed and tested to comply with
                                                               ®
                                                        battery charging during                          applicable regulations regarding EMC and shall be installed and put into
                                                        power mains                                      service according to the EMC information stated as follows.
                                                        interruptions it is
                     0% U ; 250/300   0% U ; 250/300
        IEC             T                 T            recommended that the
        61000-4-11   cycles           cycles            ProPex  II charger be
                                                               ®
                                                        powered from a separate                          Use of portable phones or other radio frequency (RF) emitting
                                                        power supply (UPS, etc.).                        equipment near the product may cause unexpected or adverse
                                                                                                         operation.
                                                        Power frequency
                                                        magnetic fields should be                        The product must not be used adjacent to, or stacked with, other
                                                        at levels characteristic of                      equipment. If adjacent or stacked use is necessary, the product must
        Rated power                                     a typical public low-                            be tested to verify normal operation in the configuration in which it is
        frequency    30 A/m           30 A/m            voltage power supply                             being used.
        magnetic     50 or 60 Hz      50 or 60 Hz       network that supplies
        fields                                          buildings used of
                                                        domestic purposes,
                                                        commercial or hospital,
                                                        clinic environment.
        NOTE: U  is the a.c. mains voltage prior to application of the test level.
               T


















       180/184                          B EU PIIS DFU PRT / Rev.04 / 02-2018 (Old ZF 1902127.X)  B EU PIIS DFU PRT / Rev.04 / 02-2018 (Old ZF 1902127.X)           169/184