Page 88 - Vessel Sanitation Program 2018 Construction Guidelines
P. 88

VSP 2018 Construction Guidelines



                                        Install separate pumps and piping not connected to the POTABLE
                                        WATER distribution system for draining tanks (Figure 18).






















































                   22.8  Suction Lines

                          Place suction lines at least 150 millimeters (6 inches) from the tank bottom or sump
                          bottom.


                   22.9  Potable Water Distribution System

                       22.9.1   Location
                                Locate DISTILLATE, PERMEATE, and distribution lines at least
                                450 millimeters (18 inches) above the deck plating or the normal bilge water
                                level.

                                Avoid BLIND LINES in the POTABLE WATER distribution system.