Page 10 - Booklet on Workshop on Industry4. with CIMCO
P. 10

Workshop  on Industry 4.0 using CIMCO products




                        6. Different way of live data collection using CIMCO-MDC

                                                             As mentioned in chapter no. 4, there are  chal-
                                                             lenges to capture the live data from the manu-
                                                             facturing machines.
                                                             In the shop floor, there are many different ma-
                                                             chines, with different control systems, PLCs, or
                                                             even the hard wired  systems. But as a end us-
                                                             er, one needs to have one common software to
                                                             take care of all the issues. There are some  soft-
                                                             ware    companies  who  can  offer  the  solution
                                                             but  are  facing  a  problem  to  arrive  on  a  com-
                                                             mon solution for all types of machines. CIMCO
                                                             has found a solution. CIMCO-MDC gives differ-
                                                             ent options. Depending upon the machine con-
                                                             trol, software  can be configured to get the live
                                                             data  on  line.  Following  are  the  few  ways  to
                                                             capture live data :

                          1)   Using FOCAS2 interface in Fanuc Systems
                          2)   Using DPRNT Commands
                          3)   Using Data Input device MOXA E-1210
                          4)   Using AUX relays in Haas system
                          5)   Using MTConnect interface
                          6)   Using Profibus interface
                          7)   Using MODBUS TCP interface
                          8)   Using Data Input output device MOXA E-1214