Page 60 - scales manual v1014 web
P. 60
PENNSYLVANIA 7400M

1. PRINT key bypasses, TARE key enters, ZERO key increments.
2. Press square black cal button inside indicator
3. CAL 10, Push PRINT
4. CAL 20, Push PRINT
5. CAL 40, PRINT
6. FIL 41, PRINT
7. NOL 42, zero scale, push PRINT
8. HLF 43, any weight on scale, push TARE, increment weight, load scale and push

PRINT.
9. Full 44, enter same weight as half, push PRINT.
10. NOL 45, weight off scale, push PRINT.
11. CAL 80, enter 0, PRINT

PENNSYLVANIA 7700

1. ZERO=ENTER, UNIT=INCREMENT, PRINT=ADVANCE, SET=DECIMAL
2. Press Cal button, CAL 20 is displayed
3. Key in 40, press ZERO
4. Press ZERO, nol 42 is displayed
5. Remove weight and press ZERO
6. HLF 43, add weight, key in value, press ZERO
7. FUL 44, add weight, key in value, press ZERO
8. Nol 45, remove weight and press ZERO
9. CAL 60 is displayed, key in “0” and press ZERO

PENNSYLVANIA MDL64

1. Cal button=d.p./clr(press once for decimal point, twice for clear), PRINT = ENTER,
TARE = ADVANCE, ZERO = INCREMENT

2. Same as 7700
PENNSYLVANIA PPI-30

1. Slide memory switch OFF, push CAL button
2. Press the 0 key
3. Place weight on Platform
4. Key in Cal weight value and press TEST
5. Slide Memory button, Press CAL button

© 2014 ScaleResource.com Page 60
   55   56   57   58   59   60   61   62   63   64   65